Abstract
Aim: The aim of the study was to assess the incremental cost-effectiveness ratio (ICER) of Cardiac Resynchronization Therapy in combination with an Implantable Cardioverter Defibrillator (CRT-D) plus Optimal Pharmacological Therapy (OPT) compared to OPT alone in patients with chronic heart failure.
Methods and results: A decision analytic model was used to estimate the ICER from a German Health Care System perspective. Effectiveness data were used as reported in the COMPANION study. Direct medical costs were considered for inpatient and outpatient treatments. Resource utilization was valued by the prices charged in 2005. Costs and effects were discounted by a discount rate of 3% per year. One-way and two-way sensitivity analyses were performed. The base-case analysis resulted in accumulated discounted QALYs of 0.958 for OPT, respectively 1.261 for CRT-D + OPT. Accumulated discounted costs were 4618 Euro for OPT, and 31 292 Euro for CRT-D + OPT, respectively, thus resulting in incremental costs per QALY gained of 88 143 Euro after two years. Considering a device longevity of seven years, this resulted in incremental costs per QALY of 24 650 Euro.
Conclusion: CRT-D plus OPT may be a cost-effective alternative for the treatment of patients with CHF in NYHA functional class III and IV depending on device longevity.
Similar articles
-
A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure.Eur J Health Econ. 2016 Dec;17(9):1159-1172. doi: 10.1007/s10198-015-0752-3. Epub 2016 Jan 4. Eur J Health Econ. 2016. PMID: 26728985 Free PMC article. Review.
-
The long-term cost-effectiveness of cardiac resynchronization therapy with or without an implantable cardioverter-defibrillator.Eur Heart J. 2007 Jan;28(1):42-51. doi: 10.1093/eurheartj/ehl382. Epub 2006 Nov 16. Eur Heart J. 2007. PMID: 17110403
-
Cost effectiveness of cardiac resynchronization therapy in the Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) trial.J Am Coll Cardiol. 2005 Dec 20;46(12):2311-21. doi: 10.1016/j.jacc.2005.08.033. J Am Coll Cardiol. 2005. PMID: 16360064
-
Cost-Effectiveness of Adding Cardiac Resynchronization Therapy to an Implantable Cardioverter-Defibrillator Among Patients With Mild Heart Failure.Ann Intern Med. 2015 Sep 15;163(6):417-26. doi: 10.7326/M14-1804. Ann Intern Med. 2015. PMID: 26301323 Free PMC article.
-
Economic Considerations of Cardiovascular Implantable Electronic Devices for The Treatment of Heart Failure.Curr Heart Fail Rep. 2024 Jun;21(3):186-193. doi: 10.1007/s11897-024-00664-y. Epub 2024 Apr 25. Curr Heart Fail Rep. 2024. PMID: 38662154 Review.
Cited by
-
Implantable cardiac defibrillators for people with non-ischaemic cardiomyopathy.Cochrane Database Syst Rev. 2018 Dec 8;12(12):CD012738. doi: 10.1002/14651858.CD012738.pub2. Cochrane Database Syst Rev. 2018. PMID: 30537022 Free PMC article.
-
Impact of oxygen uptake efficiency slope as a marker of cardiorespiratory reserve on response to cardiac resynchronization therapy.Clin Res Cardiol. 2011 Feb;100(2):159-66. doi: 10.1007/s00392-010-0226-7. Epub 2010 Sep 23. Clin Res Cardiol. 2011. PMID: 20862588 Clinical Trial.
-
Economic Evaluations in Electrophysiology in the Last 15 Years: A Systematic Review of the Literature.Rev Cardiovasc Med. 2025 Apr 23;26(4):36206. doi: 10.31083/RCM36206. eCollection 2025 Apr. Rev Cardiovasc Med. 2025. PMID: 40351680 Free PMC article.
-
Optimizing chronic disease management mega-analysis: economic evaluation.Ont Health Technol Assess Ser. 2013 Sep 1;13(13):1-148. eCollection 2013. Ont Health Technol Assess Ser. 2013. PMID: 24228076 Free PMC article. Review.
-
A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure.Eur J Health Econ. 2016 Dec;17(9):1159-1172. doi: 10.1007/s10198-015-0752-3. Epub 2016 Jan 4. Eur J Health Econ. 2016. PMID: 26728985 Free PMC article. Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials