Radiation exposure to surgical staff during F-18-FDG-guided cancer surgery
- PMID: 17955240
- DOI: 10.1007/s00259-007-0532-0
Radiation exposure to surgical staff during F-18-FDG-guided cancer surgery
Abstract
Purpose: High-energy gamma probes have recently become commercially available, developed for (18)F-FDG probe-guided surgery. The radiation received by the staff in the operating room might limit the use of it, but has never been determined. We therefore wanted to measure the absorbed staff doses at operations where patients had received a preoperative injection of (18)F-FDG.
Methods: Thirty-four patients with different cancers (breast cancer, melanoma, gastrointestinal cancers, respectively) were operated. At every operation the surgeon was monitored with a TLD tablet on his finger of the operating hand and a TLD tablet on the abdomen. The surgeon and anaesthesiologist were also monitored using electronic dosimeters placed in the trousers lining at 25 operations.
Results: The dose rate to the surgeon's abdominal wall varied between 7.5-13.2 microSv/h, depending on tumour location. The doses to the anaesthesiologists and the finger doses to the surgeon were much lower. About 350-400 MBq, i.e. ca. eight times higher activities than those used in the present study are supposed to be necessary for guiding surgery. It can be calculated from the body doses measured that a surgeon can perform between 150-260 h of surgery without exceeding permissible limits for professional workers.
Conclusions: The radiation load to the operating staff will generally be so small that it does not present any limitation for FDG-guided surgery. However, it is recommended to monitor the surgical staff considering that the surgeon may be exposed to other radiation sources, and since the staff often includes women of child-bearing age.
Similar articles
-
Comprehensive evaluation of occupational radiation exposure to intraoperative and perioperative personnel from 18F-FDG radioguided surgical procedures.Eur J Nucl Med Mol Imaging. 2008 Nov;35(11):2026-34. doi: 10.1007/s00259-008-0880-4. Epub 2008 Jul 10. Eur J Nucl Med Mol Imaging. 2008. PMID: 18618106
-
Technologist radiation exposure in routine clinical practice with 18F-FDG PET.J Nucl Med Technol. 2005 Sep;33(3):175-9. J Nucl Med Technol. 2005. PMID: 16145226
-
Occupational radiation dose of personnel involved in sentinel node biopsy procedure.Phys Med. 2021 Nov;91:117-120. doi: 10.1016/j.ejmp.2021.10.019. Epub 2021 Nov 10. Phys Med. 2021. PMID: 34773831
-
Measurements of occupational exposure for a technologist performing 18F FDG PET scans.Health Phys. 2004 Nov;87(5):539-44. doi: 10.1097/01.hp.0000137180.85643.9d. Health Phys. 2004. PMID: 15551792
-
Probe-guided localization of cancer deposits using [18F]fluorodeoxyglucose.Q J Nucl Med Mol Imaging. 2008 Mar;52(1):37-49. Q J Nucl Med Mol Imaging. 2008. PMID: 17657203 Review.
Cited by
-
Intraoperative biophotonic imaging systems for image-guided interventions.Nanophotonics. 2019 Jan;8(1):99-116. doi: 10.1515/nanoph-2018-0134. Epub 2018 Dec 14. Nanophotonics. 2019. PMID: 31187017 Free PMC article.
-
Cerenkov luminescence imaging (CLI) for image-guided cancer surgery.Clin Transl Imaging. 2016;4(5):353-366. doi: 10.1007/s40336-016-0183-x. Epub 2016 May 24. Clin Transl Imaging. 2016. PMID: 27738626 Free PMC article. Review.
-
Practice and prospects for PET/CT guided interventions.Q J Nucl Med Mol Imaging. 2021 Mar;65(1):20-31. doi: 10.23736/S1824-4785.21.03291-X. Epub 2021 Jan 26. Q J Nucl Med Mol Imaging. 2021. PMID: 33494585 Free PMC article. Review.
-
Comprehensive evaluation of occupational radiation exposure to intraoperative and perioperative personnel from 18F-FDG radioguided surgical procedures.Eur J Nucl Med Mol Imaging. 2008 Nov;35(11):2026-34. doi: 10.1007/s00259-008-0880-4. Epub 2008 Jul 10. Eur J Nucl Med Mol Imaging. 2008. PMID: 18618106
-
A comprehensive overview of radioguided surgery using gamma detection probe technology.World J Surg Oncol. 2009 Jan 27;7:11. doi: 10.1186/1477-7819-7-11. World J Surg Oncol. 2009. PMID: 19173715 Free PMC article. Review.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical