. 2008 Mar;35(3):624-9.
doi: 10.1007/s00259-007-0532-0. Epub 2007 Oct 23.

Radiation exposure to surgical staff during F-18-FDG-guided cancer surgery

Affiliations

Radiation exposure to surgical staff during F-18-FDG-guided cancer surgery

P A Andersen et al. Eur J Nucl Med Mol Imaging. 2008 Mar.

Abstract

Purpose: High-energy gamma probes have recently become commercially available, developed for (18)F-FDG probe-guided surgery. The radiation received by the staff in the operating room might limit the use of it, but has never been determined. We therefore wanted to measure the absorbed staff doses at operations where patients had received a preoperative injection of (18)F-FDG.

Methods: Thirty-four patients with different cancers (breast cancer, melanoma, gastrointestinal cancers, respectively) were operated. At every operation the surgeon was monitored with a TLD tablet on his finger of the operating hand and a TLD tablet on the abdomen. The surgeon and anaesthesiologist were also monitored using electronic dosimeters placed in the trousers lining at 25 operations.

Results: The dose rate to the surgeon's abdominal wall varied between 7.5-13.2 microSv/h, depending on tumour location. The doses to the anaesthesiologists and the finger doses to the surgeon were much lower. About 350-400 MBq, i.e. ca. eight times higher activities than those used in the present study are supposed to be necessary for guiding surgery. It can be calculated from the body doses measured that a surgeon can perform between 150-260 h of surgery without exceeding permissible limits for professional workers.

Conclusions: The radiation load to the operating staff will generally be so small that it does not present any limitation for FDG-guided surgery. However, it is recommended to monitor the surgical staff considering that the surgeon may be exposed to other radiation sources, and since the staff often includes women of child-bearing age.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Ann Nucl Med. 2005 Feb;19(1):23-8 - PubMed
    1. Ann ICRP. 1998;28(3):1-126 - PubMed
    1. Clin Nucl Med. 2005 Dec;30(12):787-91 - PubMed
    1. Ann Surg Oncol. 2016 Dec;23(Suppl 5):9020-9027 - PubMed
    1. J Surg Res. 2001 Mar;96(1):120-6 - PubMed

Substances

LinkOut - more resources