Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Sep-Oct;90(5):1242-9.

Stability-indicating reversed-phase liquid chromatographic method for simultaneous determination of simvastatin and ezetimibe from their combination drug products

Affiliations
  • PMID: 17955968

Stability-indicating reversed-phase liquid chromatographic method for simultaneous determination of simvastatin and ezetimibe from their combination drug products

Bharat G Chaudhari et al. J AOAC Int. 2007 Sep-Oct.

Abstract

A simple, precise, and rapid stability-indicating reversed-phase column liquid chromatographic (RP-LC) method has been developed and subsequently validated for simultaneous estimation of simvastatin (SIM) and ezetimibe (EZE) from their combination drug product. The proposed RP-LC method utilizes a LiChrospher 100 C18, 5 microm, 250 x 4.0 mm id column at ambient temperature; optimum mobile phase consisting of acetonitrile-water-methanol (60 + 25 + 15, v/v/v) with apparent pH adjusted to 4.0 +/- 0.1; mobile phase flow rate of 1.5 mL/min; and ultraviolet detection at 238 nm. SIM, EZE, and their combination drug product were exposed to thermal, photolytic, hydrolytic, and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. There were no other coeluting, interfering peaks from excipients, impurities, or degradation products due to variable stress conditions, and the method is specific for the estimation of SIM and EZE in the presence of degradation products. The described method was linear over the range of 1-80 and 3-80 microg/mL for SIM and EZE, respectively. The mean recoveries were 99.17 and 100.43% for SIM and EZE, respectively. The intermediate precision data were obtained under different experimental conditions, and the calculated value of the coefficient of variation was found to be less than the critical value. The proposed method can be useful in the quality control of bulk manufacturing and pharmaceutical dosage forms.

PubMed Disclaimer

Similar articles

Cited by