Using marker pens on patients: a potential source of cross infection with MRSA
- PMID: 17959001
- PMCID: PMC2121293
- DOI: 10.1308/003588407X209419
Using marker pens on patients: a potential source of cross infection with MRSA
Abstract
Introduction: Marker pens are widely used in surgery but pre-operative marking of patients may be a cause of bacterial cross-infection.
Patients and methods: Two experiments were performed to assess whether marking pens can be cause of cross-infection: (i) 26 indelible marker pens were collected from surgical wards for analysis; and (ii) 'fresh' as well as 'dry' (artificially dried by removing cap and exposing tip for 2 h) new permanent marker pens, and whiteboard marker pens were inoculated by dipping the tips into various concentrations of methicillin-resistant Staphylococcus aureus (MRSA). Each pen was inoculated onto 2 blood agar plates at 0 (immediately after inoculation) to 30 min at various intervals, 4 h and 24 h. The plates were incubated for 18 h at 35 degrees C in an incubator.
Results: Of 26 pens collected from the wards, 2 cultured Micrococci spp. (skin commensals). The constituents of new 'fresh' pen tips rapidly kill MRSA - in all cases by 4 h, but usually within minutes. At high inoculum concentrations, MRSA is not killed immediately. Dry marker pens harbour MRSA for at least 30 min and probably longer.
Conclusions: Marker pens can act as fomites for nosocomial infection. The ethanol-based ink in permanent marker pens has a bactericidal action against MRSA that starts within seconds, and they are likely to be safe to use with a gap of at least 2 min between patients. Usually, harmless skin commensals are not pathogenic except in immunocompromised patients. Old or dried-out marker pens can harbour pathogens and should be discarded before attempted use on patients. We recommend disposable markers for the immunocompromised and patients with a known positive MRSA status.
References
-
- National Patient Safety Agency. Patient Safety Alert: Correct Site Surgery. London: National Patient Safety Agency; 2005.
-
- Cohen HA, Amir J, Matalon A, Mayan R, Beni S, Barzilai A. Stethoscopes and otoscopes – a potential vector of infection? Family Practice. 1997;14:446–9. - PubMed
-
- Datz C, Jungwirth A, Dusch H. What's on doctors' ball point pens? Lancet. 1997;350:1824. - PubMed
-
- Wilson M. Microbial inhabitants of humans: their ecology and role in health and disease. Cambridge: Cambridge University Press; 2005. pp. 82–7.
-
- Banerjee D, Fraise A, Chana K. Writing pens are an unlikely vector of cross-infection with methicillin resistant Staphylococcus aureus (MRSA) J Hosp Infect. 1999;43:73–5. - PubMed