Clathrate nanostructures for mass spectrometry
- PMID: 17960240
- DOI: 10.1038/nature06195
Clathrate nanostructures for mass spectrometry
Abstract
The ability of mass spectrometry to generate intact biomolecular ions efficiently in the gas phase has led to its widespread application in metabolomics, proteomics, biological imaging, biomarker discovery and clinical assays (namely neonatal screens). Matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization have been at the forefront of these developments. However, matrix application complicates the use of MALDI for cellular, tissue, biofluid and microarray analysis and can limit the spatial resolution because of the matrix crystal size (typically more than 10 mum), sensitivity and detection of small compounds (less than 500 Da). Secondary-ion mass spectrometry has extremely high lateral resolution (100 nm) and has found biological applications although the energetic desorption/ionization is a limitation owing to molecular fragmentation. Here we introduce nanostructure-initiator mass spectrometry (NIMS), a tool for spatially defined mass analysis. NIMS uses 'initiator' molecules trapped in nanostructured surfaces or 'clathrates' to release and ionize intact molecules adsorbed on the surface. This surface responds to both ion and laser irradiation. The lateral resolution (ion-NIMS about 150 nm), sensitivity, matrix-free and reduced fragmentation of NIMS allows direct characterization of peptide microarrays, direct mass analysis of single cells, tissue imaging, and direct characterization of blood and urine.
Similar articles
-
Nanoparticle-assisted laser desorption/ionization based mass imaging with cellular resolution.Anal Chem. 2008 Jun 15;80(12):4761-6. doi: 10.1021/ac800081z. Epub 2008 May 14. Anal Chem. 2008. PMID: 18476721
-
A high-resolution scanning microprobe matrix-assisted laser desorption/ionization ion source for imaging analysis on an ion trap/Fourier transform ion cyclotron resonance mass spectrometer.Rapid Commun Mass Spectrom. 2008 Oct;22(20):3275-85. doi: 10.1002/rcm.3733. Rapid Commun Mass Spectrom. 2008. PMID: 18819119
-
Laser desorption-ionization of lipid transfers: tissue mass spectrometry imaging without MALDI matrix.Anal Chem. 2010 Jun 15;82(12):4994-7. doi: 10.1021/ac100661h. Anal Chem. 2010. PMID: 20491444
-
The synergy of elemental and biomolecular mass spectrometry: new analytical strategies in life sciences.Chem Soc Rev. 2009 Jul;38(7):1969-83. doi: 10.1039/b618635c. Epub 2009 Apr 16. Chem Soc Rev. 2009. PMID: 19551177 Review.
-
Detection Technologies. Ambient mass spectrometry.Science. 2006 Mar 17;311(5767):1566-70. doi: 10.1126/science.1119426. Science. 2006. PMID: 16543450 Review.
Cited by
-
Comprehensive bioimaging with fluorinated nanoparticles using breathable liquids.Nat Commun. 2015 Jan 20;6:5998. doi: 10.1038/ncomms6998. Nat Commun. 2015. PMID: 25601659 Free PMC article.
-
Rapid characterization of the activities of lignin-modifying enzymes based on nanostructure-initiator mass spectrometry (NIMS).Biotechnol Biofuels. 2018 Sep 27;11:266. doi: 10.1186/s13068-018-1261-2. eCollection 2018. Biotechnol Biofuels. 2018. PMID: 30275906 Free PMC article.
-
MALDI-mass spectrometric imaging for the investigation of metabolites in Medicago truncatula root nodules.J Vis Exp. 2014 Mar 5;(85):51434. doi: 10.3791/51434. J Vis Exp. 2014. PMID: 24637669 Free PMC article.
-
Protons are one of the limiting factors in determining sensitivity of nano surface-assisted (+)-mode LDI MS analyses.J Am Soc Mass Spectrom. 2013 Oct;24(10):1489-92. doi: 10.1007/s13361-013-0713-y. Epub 2013 Aug 18. J Am Soc Mass Spectrom. 2013. PMID: 23955002
-
Mass Spectrometry Imaging of Metabolites by Nanostructure Initiator Mass Spectrometry with Fluorinated Gold Nanoparticles.Methods Mol Biol. 2022;2437:117-125. doi: 10.1007/978-1-0716-2030-4_8. Methods Mol Biol. 2022. PMID: 34902144
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources