Evaluation of immunoturbidimetric specific protein methods using the Architect ci8200: comparison with immunonephelometry
- PMID: 17961307
- DOI: 10.1258/000456307782268237
Evaluation of immunoturbidimetric specific protein methods using the Architect ci8200: comparison with immunonephelometry
Abstract
Background: Specific proteins have traditionally been analyzed using methodologies such as immunonephelometry on specialized analyzers. It is now possible to perform specific protein testing on clinical chemistry analyzers using immunoturbidimetry. Performance characteristics of turbidimetric assays for eight common specific proteins were evaluated against a nephelometric method.
Methods: The Abbott Architect ci8200 and the Beckman Immage were used to perform IgA, IgG, IgM, C3, C4, haptoglobin, and transferrin testing. Abbott, Sentinel and Roche reagents were used to perform CRP testing on the ci8200. The specific protein assays were evaluated for precision, linearity, limit of detection, functional sensitivity, method comparison, prozone, and workflow.
Results: Total precision for the immunoturbidimetric assays was consistently better than 2% CV and linear throughout the dynamic range of the assays (recovery +/- 10% of target values). The limits of detection, functional sensitivities, and accuracy (as determined by performance against target values for proficiency testing samples and reference materials) are suitable for clinical purposes. Method comparison, as determined by correlation coefficients, and performance against proficiency testing samples, demonstrated good agreement between the turbidimetric and nephelometric tests. Both the turbidimetric and nephelometric assays provided reliable results under conditions of antigen excess. Specific protein test requests could be consolidated within our routine chemistry workload without impacting analytical test throughput.
Conclusions: As demonstrated by their performance characteristics, the Architect ci8200 immunoturbidimetric specific protein assays are suitable for routine use and correlate well with representative immunonephelometric assays on the Beckman Immage analyzer. The ability to perform specific protein analyses on an integrated clinical chemistry/immunoassay system can allow for consolidation of testing on a single platform, resulting in improved laboratory operations efficiency.
Similar articles
-
Comparison of immunoturbidimetric and immunonephelometric assays for specific proteins.Clin Biochem. 2009 Oct;42(15):1568-71. doi: 10.1016/j.clinbiochem.2009.06.016. Epub 2009 Jun 26. Clin Biochem. 2009. PMID: 19560450
-
Evaluation of analytical methods and workflow performance of the Architect ci8200 integrated serum/plasma analyzer system.Clin Chim Acta. 2005 Jul 1;357(1):43-54. doi: 10.1016/j.cccn.2005.01.032. Epub 2005 Apr 15. Clin Chim Acta. 2005. PMID: 15963793
-
[Normal values of IgA, IgG, IgM, a1-antitrypsin, C2-complement, C4-complement, ceruloplasmin, haptoglobin and transferrin in serum of healthy, matured newborns and comparison with adults. Method: kinetic nephelometry. (author's transl)].Klin Padiatr. 1981 Mar;193(2):88-90. doi: 10.1055/s-2008-1034437. Klin Padiatr. 1981. PMID: 6971957 German.
-
Laboratory assessment of the acute phase response: using CRP as a model.Methods Mol Biol. 2003;225:343-52. doi: 10.1385/1-59259-374-7:343. Methods Mol Biol. 2003. PMID: 12769501 Review. No abstract available.
-
Immunonephelometric and immunoturbidimetric assays for proteins.Crit Rev Clin Lab Sci. 1983;18(3):213-60. doi: 10.3109/10408368209085072. Crit Rev Clin Lab Sci. 1983. PMID: 6339164 Review.
Cited by
-
Challenges in investigating patients with isolated decreased serum IgM: The SIMcal study.Scand J Immunol. 2019 Jun;89(6):e12763. doi: 10.1111/sji.12763. Epub 2019 Apr 25. Scand J Immunol. 2019. PMID: 30887554 Free PMC article.
-
Does aging affect the immune status? A comparative analysis in 300 healthy volunteers from France, Austria and Spain.Immun Ageing. 2013 Sep 6;10(1):38. doi: 10.1186/1742-4933-10-38. Immun Ageing. 2013. PMID: 24010581 Free PMC article.
-
Impact-Induced Muscle Damage: Performance Implications in Response to a Novel Collision Simulator and Associated Timeline of Recovery.J Sports Sci Med. 2018 Aug 14;17(3):417-425. eCollection 2018 Sep. J Sports Sci Med. 2018. PMID: 30116115 Free PMC article.
-
Comparison of reference systems in the assessment of age-related serum immunoglobulin levels in pediatric patients.Turk J Med Sci. 2019 Feb 11;49(1):147-152. doi: 10.3906/sag-1805-220. Turk J Med Sci. 2019. PMID: 30764591 Free PMC article.
-
Multi-trajectory analysis of C-reactive protein and low back pain from adolescence to early adulthood.Eur Spine J. 2021 Apr;30(4):1028-1034. doi: 10.1007/s00586-020-06677-0. Epub 2021 Jan 3. Eur Spine J. 2021. PMID: 33392755
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous