Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Nov 15;69(4):1110-6.
doi: 10.1016/j.ijrobp.2007.04.075.

Rectal dose-volume differences using proton radiotherapy and a rectal balloon or water alone for the treatment of prostate cancer

Affiliations

Rectal dose-volume differences using proton radiotherapy and a rectal balloon or water alone for the treatment of prostate cancer

Carlos Vargas et al. Int J Radiat Oncol Biol Phys. .

Abstract

Purpose: To describe dose-volume values with the use of water alone vs. a rectal balloon (RB) for the treatment of prostate cancer with proton therapy.

Materials and methods: We analyzed 30 proton plans for 15 patients who underwent CT and MRI scans with an RB or water alone. Simulation was performed with a modified MRI endorectal coil and an RB with 100 mL of water or water alone. Doses of 78-82 gray equivalents were prescribed to the planning target volume. The two groups were compared for three structures: rectum, rectal wall (RW), and rectal wall 7 cm (RW7) at the level of the planning target volume.

Results: Rectum and RW volumes radiated to low, intermediate, and high doses were small: rectum V10, 33.7%; V50, 17.3%; and V70, 10.2%; RW V10, 32.4%; V50, 20.4%; and V70, 14.6%. The RB effectively increased the rectal volume for all cases (139.8 +/- 44.9 mL vs. 217.7 +/- 32.2 mL (p < 0.001). The RB also decreased the volume of the rectum radiated to doses V10-V65 (p < or = 0.05); RW for V10-V50; and RW7 for V10-V35. An absolute rectum V50 improvement >5% was seen for the RB in 5 of 15 cases, for a benefit of 9.2% +/- 2.3% compared with 2.4% +/- 1.3% for the remaining 10 cases (p < 0.001). Similar benefit was seen for the rectal wall. No benefit was seen for doses > or =70 gray equivalents for the rectum, RW, or RW7. No benefit of < or =1% was seen with an RB in 46% for the rectum V70 and in 40% for the rectal wall V70.

Conclusions: Rectum and rectal wall doses with proton radiation were low whether using water or an RB. Selected patients will have a small but significant advantage with an RB; however, water alone was well tolerated and will be an alternative for most patients.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources