Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 May;19(5):2087-96.
doi: 10.1007/s10856-007-3293-1. Epub 2007 Oct 30.

Effect of thin carbonate-containing apatite (CA) coating of titanium fiber mesh on trabecular bone response

Affiliations

Effect of thin carbonate-containing apatite (CA) coating of titanium fiber mesh on trabecular bone response

Tohru Hayakawa et al. J Mater Sci Mater Med. 2008 May.

Abstract

The influence of thin carbonate-containing apatite (CA) coating on trabecular bone response to cylindrical titanium fiber mesh (porosity of 85%, pore size of 200-300 microm, 2.8 mm diameter x 6 mm length) implants was investigated. Thin CA coatings were deposited by the so-called molecular precursor method. Molecular precursor solution was obtained by adding dibutylammonium diphosphate salt to Ca-EDTA/amine ethanol solution by adjusting Ca/P = 1.67. Sintered cylindrical titanium fiber mesh was immersed into molecular precursor solution and then tempered at 600 degrees C for 2 h. The immersion and tempering process was repeated three times. An adherent thin CA film could be deposited on the inside of titanium fiber mesh. After the immersion of a CA-coated titanium fiber mesh in simulated body fluid, apatite crystals precipitated on the titanium fiber mesh. Uncoated and CA-coated titanium fiber mesh was inserted into the trabecular bone of the left and right femoral condyles of rabbits. Histological and histomorphometrical evaluation revealed a significantly greater amount of bone formation inside the porous area of the CA-coated titanium fiber mesh after 12 weeks of implantation. The present results suggested that a thin CA-coated titanium mesh has better osteoconductivity and will be useful for a three-dimensional scaffold.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Biomaterials. 2005 Oct;26(30):6014-23 - PubMed
    1. Biomaterials. 1991 Oct;12(8):767-74 - PubMed
    1. J Biomed Mater Res B Appl Biomater. 2005 Oct;75(1):168-76 - PubMed
    1. J Biomed Mater Res A. 2003 Dec 15;67(4):1305-9 - PubMed
    1. J Biomed Mater Res A. 2006 Jan;76(1):16-24 - PubMed

Publication types

LinkOut - more resources