ISCEV guidelines for clinical multifocal electroretinography (2007 edition)
- PMID: 17972125
- PMCID: PMC2235911
- DOI: 10.1007/s10633-007-9089-2
ISCEV guidelines for clinical multifocal electroretinography (2007 edition)
Abstract
The clinical multifocal electroretinogram (mfERG) is an electrophysiological test of local retinal function. With this technique, many local ERG responses, typically 61 or 103, are recorded from the cone-driven retina under light-adapted conditions. This document specifies guidelines for performance of the test. It also provides detailed guidance on technical and practical issues, as well as on reporting test results. The main objective of the guidelines is to promote consistent quality of mfERG testing and reporting within and among centers. These 2007 guidelines, from the International Society for Clinical Electrophysiology of Vision (ISCEV: http://www.iscev.org ), replace the ISCEV guidelines for the mfERG published in 2003.
Figures
References
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1023/B:DOOP.0000036793.44912.45', 'is_inner': False, 'url': 'https://doi.org/10.1023/b:doop.0000036793.44912.45'}, {'type': 'PubMed', 'value': '15455793', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/15455793/'}]}
- Marmor MF, Holder GE, Seeliger MW, Yamamoto S (2004) International Society for Clinical Electrophysiology of Vision. Standard for clinical electroretinography (2004 update). Doc Ophthalmol 108:107–114 - PubMed
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1023/A:1022591317907', 'is_inner': False, 'url': 'https://doi.org/10.1023/a:1022591317907'}, {'type': 'PubMed', 'value': '12678274', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/12678274/'}]}
- Marmor MF, Hood D, Keating D, Kondo M, Seeliger MW, Miyake Y (2003) Guidelines for basic multifocal electroretinography (mfERG). Doc Ophthalmol 106:105–115 - PubMed
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1007/s10633-007-9053-1', 'is_inner': False, 'url': 'https://doi.org/10.1007/s10633-007-9053-1'}, {'type': 'PMC', 'value': 'PMC1896293', 'is_inner': False, 'url': 'https://pmc.ncbi.nlm.nih.gov/articles/PMC1896293/'}, {'type': 'PubMed', 'value': '17435967', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/17435967/'}]}
- Holder GE, Brigell M, Hawlina M, Meigen T, Vaegan, Bach M (2007) Standard for pattern electroretinography. Doc Ophthalmol 114:111–116 - PMC - PubMed
-
- {'text': '', 'ref_index': 1, 'ids': [{'type': 'DOI', 'value': '10.1023/A:1026244901657', 'is_inner': False, 'url': 'https://doi.org/10.1023/a:1026244901657'}, {'type': 'PubMed', 'value': '14661909', 'is_inner': True, 'url': 'https://pubmed.ncbi.nlm.nih.gov/14661909/'}]}
- Brigell M, Bach M, Barber C, Moskowitz A, Robson J (2003) Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Doc Ophthalmol 107:185–193 - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources