Three-year clinical performance of cast gold vs ceramic partial crowns
- PMID: 17973129
- DOI: 10.1007/s00784-007-0158-4
Three-year clinical performance of cast gold vs ceramic partial crowns
Abstract
Cast gold partial crowns (CGPC) and partial ceramic crowns (PCC) are both accepted for restoring posterior teeth with extended lesions today. However, as esthetics in dentistry becomes increasingly important, CGPC are being progressively replaced by PCC. The aim of the present prospective split-mouth study was the comparison of the clinical performance of PCC and CGPC after 3 years of clinical service. Twenty-eight patients (11 men and 17 women) participated in the 3-year recall with a total of 56 restorations. In each patient, one CGPC (Degulor C) and one PCC (Vita Mark II ceramic/Cerec III) had been inserted at baseline. CGPC were placed using a zinc phosphate cement (Harvard); PCC were adhesively luted (Variolink II/Excite). All restorations were clinically assessed using modified US Public Health Service (USPHS) criteria at baseline, 1 year, 2 years, and 3 years after insertion. Twenty-eight CGPC and 14 PCC were placed in molars, and 14 PCC were placed in premolars. Early data were reported previously under the same study design. After 3 years, the evaluation according to USPHS criteria revealed no statistically significant differences between both types of restorations with the exception of marginal adaptation and marginal discoloration: A statistically significant difference within the PCC group (baseline/3 years) was determined for the criterion marginal adaptation. For the 3-year recall period, overall failure was 0% for CGPC and 6.9% for PCC. At 3 years, PCC meet American Dental Association Acceptance Guidelines criteria for tooth-colored restorative materials for posterior teeth.
Similar articles
-
Two-year clinical performance of cast gold vs ceramic partial crowns.Clin Oral Investig. 2006 Jun;10(2):126-33. doi: 10.1007/s00784-006-0042-7. Epub 2006 Apr 14. Clin Oral Investig. 2006. PMID: 16614863 Clinical Trial.
-
Controlled, prospective, randomized, clinical evaluation of partial ceramic crowns inserted with RelyX Unicem with or without selective enamel etching. Results after 2 years.Clin Oral Investig. 2012 Apr;16(2):451-61. doi: 10.1007/s00784-011-0516-0. Epub 2011 Mar 23. Clin Oral Investig. 2012. PMID: 21431338 Clinical Trial.
-
Controlled, prospective clinical split-mouth study of cast gold vs. ceramic partial crowns: 5.5 year results.Am J Dent. 2010 Jun;23(3):161-7. Am J Dent. 2010. PMID: 20718214 Clinical Trial.
-
Gold vs. CAD/CAM ceramic partial-crowns: 20-year randomized clinical study.Dent Mater. 2025 Aug;41(8):986-993. doi: 10.1016/j.dental.2025.06.004. Epub 2025 Jun 13. Dent Mater. 2025. PMID: 40517063 Clinical Trial.
-
Crowns and extra-coronal restorations: materials selection.Br Dent J. 2002 Feb 23;192(4):199-202, 205-11. doi: 10.1038/sj.bdj.4801334. Br Dent J. 2002. PMID: 11931483 Review.
Cited by
-
A systematic review of outcome measurements and quality of studies evaluating fixed tooth-supported restorations.J Prosthodont. 2014 Aug;23(6):421-33. doi: 10.1111/jopr.12160. Epub 2014 Jun 19. J Prosthodont. 2014. PMID: 24947268 Free PMC article.
-
Multicenter Prospective Clinical Study on Chairside-Fabricated Partial Crowns: 5-Year Results for Lithia-Zirconia Glass-Ceramic Restorations.J Esthet Restor Dent. 2025 Feb;37(2):561-570. doi: 10.1111/jerd.13328. Epub 2024 Oct 9. J Esthet Restor Dent. 2025. PMID: 39381856 Free PMC article.
-
Four-year clinical evaluation of a self-adhesive luting agent for ceramic inlays.Clin Oral Investig. 2013 Apr;17(3):739-50. doi: 10.1007/s00784-012-0762-9. Epub 2012 Jun 17. Clin Oral Investig. 2013. PMID: 22707232 Clinical Trial.
-
Marginal adaptation of three self-adhesive resin cements vs. a well-tried adhesive luting agent.Clin Oral Investig. 2009 Dec;13(4):459-64. doi: 10.1007/s00784-009-0255-7. Epub 2009 Feb 19. Clin Oral Investig. 2009. PMID: 19225814 Clinical Trial.
-
Influence of different cusp coverage methods for the extension of ceramic inlays on marginal integrity and enamel crack formation in vitro.Clin Oral Investig. 2009 Sep;13(3):333-41. doi: 10.1007/s00784-008-0239-z. Epub 2009 Jan 10. Clin Oral Investig. 2009. PMID: 19137332
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous