High-dose radioimmunotherapy with 90Y-ibritumomab tiuxetan: comparative dosimetric study for tailored treatment
- PMID: 17978355
- DOI: 10.2967/jnumed.107.044016
High-dose radioimmunotherapy with 90Y-ibritumomab tiuxetan: comparative dosimetric study for tailored treatment
Erratum in
- J Nucl Med. 2007 Dec;48(12):2027
Abstract
High-dose (90)Y-ibritumomab tiuxetan therapy and associated autologous stem cell transplantation (ASCT) were applied after dosimetry. This paper reports dosimetric findings for 3 different methods, including image corrections and actual organ mass corrections. Our first goal was to identify the most reliable and feasible dosimetric method to be adopted in high-dose therapy with (90)Y-ibritumomab tiuxetan. The second goal was to verify the safety of the prescribed activity and the best timing of stem cell reinfusion.
Methods: Twenty-two patients with refractory non-Hodgkin's lymphoma were enrolled into 3 activity groups escalating to 55.5 MBq/kg. A somewhat arbitrary cutoff of 20 Gy to organs (except red marrow) was defined as a safe limit for patient recruitment. ASCT was considered of low risk when the dose to reinfused stem cells was less than 50 mGy. (111)In-Ibritumomab tiuxetan (185 MBq) was administered for dosimetry. Blood samples were collected up to 130 h after injection to derive individual blood clearance rates and red marrow doses. Five whole-body images were acquired up to 7 d after injection. A transmission scan and a low-dose CT scan were also acquired. The conjugate-view technique was used, and images were corrected for background, scatter, and attenuation. Absorbed doses were calculated using the OLINDA/EXM software, adjusting doses for individual organ masses. The biodistribution data were analyzed for dosimetry by the conjugate-view technique using 3 methods. Method A was a patient-specific method applying background, scatter, and attenuation correction, with absorbed doses calculated using the OLINDA/EXM software and doses adjusted for individual organ masses and individually estimated blood volumes. Method B was a reference method using the organ masses of the reference man and woman phantoms. Method C was a simplified method using standard blood and red marrow volumes and no corrections.
Results: The medians and ranges (in parentheses) for dose estimates (mGy/MBq) according to method A were 1.7 (0.3-3.5) for lungs, 2.8 (1.8-10.6) for liver, 1.7 (0.6-3.8) for kidneys, 1.9 (0.8-5.0) for spleen, 0.8 (0.4-1.0) for red marrow, and 2.8 (1.3-4.7) for testes. None of patients had to postpone ASCT. Absorbed doses from method B differed from method A by up to 100% for liver, 80% for kidneys, 335% for spleen, and 80% for blood because of differences between standard and actual masses. Compared with method A, method C led to dose overestimates of up to 4-fold for lungs, 2-fold for liver, 5-fold for kidneys, 7-fold for spleen, 2-fold for red marrow, and 2-fold for testes.
Conclusion: Patient-specific dosimetry with image correction and mass adjustment is recommended in high-dose (90)Y-ibritumomab tiuxetan therapy, for which liver is the dose-limiting organ. Overly simplified dosimetry may provide inaccurate information on the dose to critical organs, the recommended values of administered activity, and the timing of ASCT.
Similar articles
-
Radiation dosimetry results and safety correlations from 90Y-ibritumomab tiuxetan radioimmunotherapy for relapsed or refractory non-Hodgkin's lymphoma: combined data from 4 clinical trials.J Nucl Med. 2003 Mar;44(3):465-74. J Nucl Med. 2003. PMID: 12621016 Clinical Trial.
-
Biodistribution, radiation dosimetry and scouting of 90Y-ibritumomab tiuxetan therapy in patients with relapsed B-cell non-Hodgkin's lymphoma using 89Zr-ibritumomab tiuxetan and PET.Eur J Nucl Med Mol Imaging. 2012 Mar;39(3):512-20. doi: 10.1007/s00259-011-2008-5. Epub 2012 Jan 5. Eur J Nucl Med Mol Imaging. 2012. PMID: 22218876 Free PMC article. Clinical Trial.
-
Dosimetry in myeloablative (90)Y-labeled ibritumomab tiuxetan therapy: possibility of increasing administered activity on the base of biological effective dose evaluation. Preliminary results.Cancer Biother Radiopharm. 2007 Feb;22(1):113-20. doi: 10.1089/cbr.2007.302. Cancer Biother Radiopharm. 2007. PMID: 17627419 Clinical Trial.
-
Yttrium-90-ibritumomab tiuxetan radioimmunotherapy: a new treatment approach for B-cell non-Hodgkin's lymphoma.Drugs Today (Barc). 2004 Feb;40(2):111-9. doi: 10.1358/dot.2004.40.2.799423. Drugs Today (Barc). 2004. PMID: 15045033 Review.
-
Administration guidelines for radioimmunotherapy of non-Hodgkin's lymphoma with (90)Y-labeled anti-CD20 monoclonal antibody.J Nucl Med. 2002 Feb;43(2):267-72. J Nucl Med. 2002. PMID: 11850494 Review.
Cited by
-
A theoretical dose-escalation study based on biological effective dose in radioimmunotherapy with (90)Y-ibritumomab tiuxetan (Zevalin).Eur J Nucl Med Mol Imaging. 2010 May;37(5):862-73. doi: 10.1007/s00259-009-1333-4. Epub 2010 Jan 13. Eur J Nucl Med Mol Imaging. 2010. PMID: 20069297
-
A new pharmacokinetic model for 90Y-ibritumomab tiuxetan based on 3-dimensional dosimetry.Sci Rep. 2018 Oct 5;8(1):14860. doi: 10.1038/s41598-018-33160-0. Sci Rep. 2018. PMID: 30291297 Free PMC article. Clinical Trial.
-
Personalized Dosimetry in Targeted Radiation Therapy: A Look to Methods, Tools and Critical Aspects.J Pers Med. 2022 Feb 2;12(2):205. doi: 10.3390/jpm12020205. J Pers Med. 2022. PMID: 35207693 Free PMC article. Review.
-
Estimates of radiation-absorbed dose to kidneys in patients treated with 90Y-ibritumomab tiuxetan.Cancer Biother Radiopharm. 2008 Oct;23(5):633-9. doi: 10.1089/cbr.2008.0506. Cancer Biother Radiopharm. 2008. PMID: 18999935 Free PMC article.
-
Absorbed dose and biologically effective dose in patients with high-risk non-Hodgkin's lymphoma treated with high-activity myeloablative 90Y-ibritumomab tiuxetan (Zevalin).Eur J Nucl Med Mol Imaging. 2009 Nov;36(11):1745-57. doi: 10.1007/s00259-009-1141-x. Epub 2009 May 20. Eur J Nucl Med Mol Imaging. 2009. PMID: 19455328 Clinical Trial.
Publication types