Comparative Study
. 2007 Nov 20;116(21):2391-8.
doi: 10.1161/CIRCULATIONAHA.107.707331. Epub 2007 Nov 5.

Outcomes of stent thrombosis and restenosis during extended follow-up of patients treated with bare-metal coronary stents

Affiliations
Comparative Study

Outcomes of stent thrombosis and restenosis during extended follow-up of patients treated with bare-metal coronary stents

Brendan Doyle et al. Circulation. .

Abstract

Background: Concern regarding risk of late thrombosis after "off-label" treatment with drug-eluting stents has prompted increased use of bare-metal stents (BMS) in current practice. The sequelae of late BMS failures, however, have been poorly characterized.

Methods and results: We performed a retrospective study of 4503 consecutive patients treated with at least 1 BMS and dual antiplatelet therapy between 1994 and 2000. The cumulative incidence of stent thrombosis was 0.5% at 30 days (95% CI, 0.3% to 0.7%), 0.8% at 1 year (95% CI, 0.6% to 1.1%), and 2.0% at 10 years (95% CI, 1.5% to 2.5%). Risk of late (30 days to 1 year) and very late (>1 year) BMS thrombosis was increased among patients considered off label for drug-eluting stent use (P=0.024). When saphenous vein graft interventions were excluded, however, risk after off-label use was not significantly increased (P=0.23). Other correlates included vein graft intervention, prior myocardial infarction (MI), peripheral vascular disease, and ulcerated lesion (P<0.001). Mortality was markedly increased after late and very late BMS thrombosis, particularly during the first 30 days (hazard ratios, 22 [95% CI, 3.1 to 159] and 40 [95% CI, 15 to 107], respectively). The 10-year incidence of clinical restenosis was 18.1% (95% CI, 16.5% to 19.7%), presenting with MI in 2.1% (95% CI, 1.6% to 2.6%). Restenosis presenting with MI was associated with increased mortality compared with no restenosis (hazard ratio, 2.37; P<0.001) and with restenosis with a non-MI presentation (hazard ratio, 2.42; P<0.001).

Conclusions: The incidence of BMS thrombosis and of MI caused by restenosis during extended follow-up is significant. Both complications are associated with mortality.

PubMed Disclaimer

Comment in

  • Et tu, bare metal stent?
    Williams DO, Abbott JD. Williams DO, et al. Circulation. 2007 Nov 20;116(21):2363-5. doi: 10.1161/CIRCULATIONAHA.107.736918. Circulation. 2007. PMID: 18025401 No abstract available.

Publication types

MeSH terms

LinkOut - more resources