. 2007 Nov-Dec;21(10):687-92.
doi: 10.1097/BOT.0b013e318158fd42.

Navigating the fluoroscope's C-arm back into position: an accurate and practicable solution to cut radiation and optimize intraoperative workflow

Affiliations

Navigating the fluoroscope's C-arm back into position: an accurate and practicable solution to cut radiation and optimize intraoperative workflow

Felix Matthews et al. J Orthop Trauma. 2007 Nov-Dec.

Abstract

Objectives: During complex image-guided orthopedic trauma procedures, repetitive fluoroscopic scout imaging is performed. A number of preparatory positioning images often must be taken to reproduce a comparable projection. These scout images have no intrinsic clinical relevance but nevertheless expose the patient and the surgical team to considerable radiation, which could be avoided. This study presents and validates a method to decrease intraoperative radiation.

Methods: Precision, time requirements, and number of scout images for repositioning the fluoroscope, with and without navigation aid, were recorded on 20 test-rig and 3 phantom setups. A commercially available image-guided surgical navigation system (Vector Vision, BrainLAB), originally designed for instrument navigation, was employed to register and retrieve the C-arm positions. A newly developed software computed the necessary moves to reposition the C-arm on an intuitive visual display.

Results: Retrieving a given C-arm position with the conventional non-navigated technique required an average of 7 scout images (range, 3 to 12 images). In contrast, navigation-assisted repositioning did not necessitate a single scout image. Deviations from the original projection were minimal for both navigated (0.9 degrees, 95% CI 0.8 to 1.1 degrees) and non-navigated repositioning (0.8 degrees, 95% CI 0.7 to 0.9 degrees). Average positioning times were comparable when navigating the C-arm (46 seconds, 95% CI 41 to 51 seconds) and in scout image-based positioning (49 seconds, 95% CI 44 to 53 seconds).

Conclusions: Navigated C-arm positioning avoids multiple scout images and yields sufficient precision for clinical deployment. Radiation exposure can be reduced considerably by a combination of instrument navigation and navigated C-arm positioning.