Real-time continuous glucose monitoring using GuardianRT: from research to clinical practice
- PMID: 17988918
- DOI: 10.1016/j.diabet.2007.05.003
Real-time continuous glucose monitoring using GuardianRT: from research to clinical practice
Abstract
The limited number of self-monitoring blood glucose measurements is an obstacle for good metabolic control in patients with type 1 diabetes. However, continuous glucose measurement with real-time data and alarms is a recent technology that promises to improve the efficacy of treatment in diabetic patients. GuardianRT uses a continuous telemetry display of real-time glucose values, and automatic alerts at preset hypo- and hyperglycaemic levels. Three calibrations a day are required, and the sensor must be changed every three days. The GuardControl study showed that, within three months, real-time continuous glucose monitoring with the GuardianRT led to significantly improved HbA1c values in 162 poorly controlled patients (children and adults) with type 1 diabetes despite intensive insulin therapy. The continuous availability of glucose measurements permitted the patients to adjust their own insulin doses, food intake and physical activity and, thus, improve their glycaemic control. This report summarizes the available data on this tool and details how best to use this state-of-the-art modality in diabetic patients in clinical practice.
Similar articles
-
Results of a randomised controlled cross-over trial on the effect of continuous subcutaneous glucose monitoring (CGMS) on glycaemic control in children and adolescents with type 1 diabetes.Exp Clin Endocrinol Diabetes. 2006 Feb;114(2):63-7. doi: 10.1055/s-2006-923887. Exp Clin Endocrinol Diabetes. 2006. PMID: 16570235 Clinical Trial.
-
[Insulin therapy by insulin pump: continuous or conventional self-blood glucose monitoring? ].Diabetes Metab. 2003 Apr;29(2 Pt 2):S54-62. Diabetes Metab. 2003. PMID: 12746628 Review. French.
-
Real-time glucose sensors in children and adolescents with type-1 diabetes.Horm Res. 2008;70(4):193-202. doi: 10.1159/000151592. Epub 2008 Sep 5. Horm Res. 2008. PMID: 18772591 Review.
-
[Therapeutic education and continuous glucose monitoring in insulin-treated diabetic patients].Rev Med Suisse. 2010 Sep 1;6(260):1596-600. Rev Med Suisse. 2010. PMID: 20853714 French.
-
Continuous glucose monitoring in managing diabetes in children.Diabetes Metab Res Rev. 2002 Jul-Aug;18(4):330-1. doi: 10.1002/dmrr.310. Diabetes Metab Res Rev. 2002. PMID: 12203949
Cited by
-
Continuous Glucose Monitoring Systems: A Review.Diagnostics (Basel). 2013 Oct 29;3(4):385-412. doi: 10.3390/diagnostics3040385. Diagnostics (Basel). 2013. PMID: 26824930 Free PMC article. Review.
-
Acute Low-Volume High-Intensity Interval Exercise and Continuous Moderate-Intensity Exercise Elicit a Similar Improvement in 24-h Glycemic Control in Overweight and Obese Adults.Front Physiol. 2017 Jan 9;7:661. doi: 10.3389/fphys.2016.00661. eCollection 2016. Front Physiol. 2017. PMID: 28119617 Free PMC article.
-
Enzyme-mediated redox initiation for hydrogel generation and cellular encapsulation.Biomacromolecules. 2009 Nov 9;10(11):3114-21. doi: 10.1021/bm900846m. Biomacromolecules. 2009. PMID: 19821604 Free PMC article.
-
A review of the management of implanted medical devices for diabetes: trends and directions.J Diabetes Sci Technol. 2008 Nov;2(6):995-1002. doi: 10.1177/193229680800200609. J Diabetes Sci Technol. 2008. PMID: 19885289 Free PMC article.
-
Continuous Glucose Monitoring (CGM) Adherence in Youth With Type 1 Diabetes: Associations With Biomedical and Psychosocial Variables.J Diabetes Sci Technol. 2017 May;11(3):476-483. doi: 10.1177/1932296816676280. Epub 2016 Nov 1. J Diabetes Sci Technol. 2017. PMID: 27807014 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical