A randomised, crossover comparison between the CobraPLA and the LMA Classic in paralysed patients
- PMID: 17991267
- DOI: 10.1111/j.1365-2044.2007.05250.x
A randomised, crossover comparison between the CobraPLA and the LMA Classic in paralysed patients
Abstract
We performed a randomised, crossover study in 38 anaesthetised and paralysed patients to compare the performance of the CobraPLA and the LMA Classic during controlled ventilation. The median (IQR [range]) airway leak pressure was 23.0 (20-24 [12-30]) cmH(2)O for the CobraPLA and 15.0 (12-19 [8-30]) cmH(2)O for the LMA Classic (p < 0.001). The median (IQR [range]) insertion time was 15.0 (11-26 [9-31]) s for the CobraPLA and 22.5 (20-25 [15-50]) s for the LMA Classic (p < 0.001). There was no significant difference between the two devices for the number of insertion and reposition attempts, the anatomical position scored by fibreoptic bronchoscopy or the peak and plateau airway pressures. There were no adverse events during anaesthesia. The CobraPLA provides a better airway leak pressure and takes less time to insert than the LMA Classic in paralysed patients. Our data show that the CobraPLA can be used to secure a patent airway during controlled ventilation in selected patients.
Similar articles
-
Randomised crossover comparison of the Ambu AuraOnce Laryngeal Mask with the LMA Classic laryngeal mask airway in paralysed anaesthetised patients.Anaesthesia. 2008 Jan;63(1):82-5. doi: 10.1111/j.1365-2044.2007.05284.x. Anaesthesia. 2008. PMID: 18086075 Clinical Trial.
-
Exposure to anaesthetic trace gases during general anaesthesia: CobraPLA vs. LMA classic.Acta Anaesthesiol Scand. 2010 Aug;54(7):848-54. doi: 10.1111/j.1399-6576.2009.02194.x. Epub 2010 Jan 6. Acta Anaesthesiol Scand. 2010. PMID: 20055764 Clinical Trial.
-
The laryngeal mask airway Supreme--a single use laryngeal mask airway with an oesophageal vent. A randomised, cross-over study with the laryngeal mask airway ProSeal in paralysed, anaesthetised patients.Anaesthesia. 2009 Jan;64(1):79-83. doi: 10.1111/j.1365-2044.2008.05682.x. Anaesthesia. 2009. PMID: 19087011 Clinical Trial.
-
Brief review: the Cobra Perilaryngeal Airway (CobraPLA and the Streamlined Liner of Pharyngeal Airway (SLIPA) supraglottic airways.Can J Anaesth. 2008 Mar;55(3):177-85. doi: 10.1007/BF03016093. Can J Anaesth. 2008. PMID: 18310629 Review.
-
Fibreoptic intubation--a case series and brief review.Med J Malaysia. 1993 Jun;48(2):200-6. Med J Malaysia. 1993. PMID: 8350796 Review.
Cited by
-
Cobra-PLA provides higher oropharyngeal leak pressure than LMA-Classic and LMA-Unique: A meta-analysis with 22 studies.Medicine (Baltimore). 2019 Jun;98(26):e15832. doi: 10.1097/MD.0000000000015832. Medicine (Baltimore). 2019. PMID: 31261492 Free PMC article.
-
Comparison of Cobra perilaryngeal airway (CobraPLA™) with flexible laryngeal mask airway in terms of device stability and ventilation characteristics in pediatric ophthalmic surgery.J Anaesthesiol Clin Pharmacol. 2012 Jul;28(3):322-5. doi: 10.4103/0970-9185.98324. J Anaesthesiol Clin Pharmacol. 2012. PMID: 22869937 Free PMC article.