An algorithm for QT interval monitoring in neonatal intensive care units
- PMID: 17993306
- DOI: 10.1016/j.jelectrocard.2007.06.019
An algorithm for QT interval monitoring in neonatal intensive care units
Abstract
QT surveillance of neonatal patients, and especially premature infants, may be important because of the potential for concomitant exposure to QT-prolonging medications and because of the possibility that they may have hereditary QT prolongation (long-QT syndrome), which is implicated in the pathogenesis of approximately 10% of sudden infant death syndrome. In-hospital automated continuous QT interval monitoring for neonatal and pediatric patients may be beneficial but is difficult because of high heart rates; inverted, biphasic, or low-amplitude T waves; noisy signal; and a limited number of electrocardiogram (ECG) leads available. Based on our previous work on an automated adult QT interval monitoring algorithm, we further enhanced and expanded the algorithm for application in the neonatal and pediatric patient population. This article presents results from evaluation of the new algorithm in neonatal patients. Neonatal-monitoring ECGs (n = 66; admission age range, birth to 2 weeks) were collected from the neonatal intensive care unit in 2 major teaching hospitals in the United States. Each digital recording was at least 10 minutes in length with a sampling rate of 500 samples per second. Special handling of high heart rate was implemented, and threshold values were adjusted specifically for neonatal ECG. The ECGs studied were divided into a development/training ECG data set (TRN), with 24 recordings from hospital 1, and a testing data set (TST), with 42 recordings composed of cases from both hospital 1 (n = 16) and hospital 2 (n = 26). Each ECG recording was manually annotated for QT interval in a 15-second period by 2 cardiologists. Mean and standard deviation of the difference (algorithm minus cardiologist), regression slope, and correlation coefficient were used to describe algorithm accuracy. Considering the technical problems due to noisy recordings, a high fraction (approximately 80%) of the ECGs studied were measurable by the algorithm. Mean and standard deviation of the error were both low (TRN = -3 +/- 8 milliseconds; TST = 1 +/- 20 milliseconds); regression slope (TRN = 0.94; TST = 0.83) and correlation coefficients (TRN = 0.96; TST = 0.85) (P < .0001) were fairly high. Performance on the TST was similar to that on the TRN with the exception of 2 cases. These results confirm that automated continuous QT interval monitoring in the neonatal intensive care setting is feasible and accurate and may lead to earlier recognition of the "vulnerable" infant.
Similar articles
-
Precision of QT interval measurement by advanced electrocardiographic equipment.Pacing Clin Electrophysiol. 2006 Nov;29(11):1277-84. doi: 10.1111/j.1540-8159.2006.00532.x. Pacing Clin Electrophysiol. 2006. PMID: 17100684
-
An algorithm for continuous real-time QT interval monitoring.J Electrocardiol. 2006 Oct;39(4 Suppl):S123-7. doi: 10.1016/j.jelectrocard.2006.05.018. Epub 2006 Aug 21. J Electrocardiol. 2006. PMID: 16920145
-
Comparison of 2 methods of measuring the QT interval.Am J Crit Care. 1998 Sep;7(5):346-54. Am J Crit Care. 1998. PMID: 9740884
-
Implications of methodological differences in digital electrocardiogram interval measurement.J Electrocardiol. 2006 Oct;39(4 Suppl):S152-6. doi: 10.1016/j.jelectrocard.2006.05.030. Epub 2006 Aug 21. J Electrocardiol. 2006. PMID: 16920141 Review.
-
Long QT syndrome genotyping by electrocardiography: fact, fiction, or something in between?J Electrocardiol. 2006 Oct;39(4 Suppl):S119-22. doi: 10.1016/j.jelectrocard.2006.06.008. Epub 2006 Aug 21. J Electrocardiol. 2006. PMID: 16920146 Review.
Cited by
-
Computerized QT and QTc Measurements From Bedside ICU Monitors Are Similar to Those Derived From a Standard 12-Lead ECG.Ann Noninvasive Electrocardiol. 2025 Jan;30(1):e70031. doi: 10.1111/anec.70031. Ann Noninvasive Electrocardiol. 2025. PMID: 39645597 Free PMC article.
-
Philips QT interval measurement algorithms for diagnostic, ambulatory, and patient monitoring ECG applications.Ann Noninvasive Electrocardiol. 2009 Jan;14 Suppl 1(Suppl 1):S3-8. doi: 10.1111/j.1542-474X.2008.00258.x. Ann Noninvasive Electrocardiol. 2009. PMID: 19143739 Free PMC article.
-
Heart-rate-corrected QT interval evolution in premature infants during the first week of life.Pediatr Cardiol. 2014 Dec;35(8):1363-9. doi: 10.1007/s00246-014-0937-z. Epub 2014 Jun 4. Pediatr Cardiol. 2014. PMID: 24894895
-
Novel Bloodless Potassium Determination Using a Signal-Processed Single-Lead ECG.J Am Heart Assoc. 2016 Jan 25;5(1):e002746. doi: 10.1161/JAHA.115.002746. J Am Heart Assoc. 2016. PMID: 26811164 Free PMC article.
-
Noninvasive blood potassium measurement using signal-processed, single-lead ecg acquired from a handheld smartphone.J Electrocardiol. 2017 Sep-Oct;50(5):620-625. doi: 10.1016/j.jelectrocard.2017.06.008. Epub 2017 Jun 8. J Electrocardiol. 2017. PMID: 28641860 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical