Quantitative assessment of severity of mitral regurgitation by serial echocardiography in a multicenter clinical trial of percutaneous mitral valve repair
- PMID: 17996523
- DOI: 10.1016/j.amjcard.2007.06.066
Quantitative assessment of severity of mitral regurgitation by serial echocardiography in a multicenter clinical trial of percutaneous mitral valve repair
Abstract
The aims of the echocardiographic substudy of this multicenter trial were to evaluate the use of quantitative assessment of mitral regurgitation (MR) severity using serial echocardiography and to assess the efficacy of percutaneous mitral valve repair. Previous surgical repair studies did not use quantitative echocardiographic methods. Results of a percutaneous mitral valve repair clip device in a core echocardiographic laboratory were evaluated. Published parameters for quantifying MR were used in a systematic protocol to qualify patients for study entry and evaluate treatment efficacy at discharge and 6 months after clip repair. Baseline results were presented for 55 patients, and follow-up results, for 49. Ninety-eight percent of required echocardiographic studies were submitted to the core laboratory, and >85% of required measurements were possible. At baseline, mean regurgitant volume was 54.8 +/- 24 ml, regurgitant fraction was 46.9 +/-16.2%, effective regurgitant orifice area was 0.71 +/- 0.40 cm(2), and vena contracta width was 0.66 +/- 0.20 cm. Based on a severity scale of 1 to 4, mean color flow grade was 3.4 +/- 0.7, and mean pulmonary vein flow was 2.8 +/- 1.2. In patients with a clip at 6 months, all measurements of MR severity were significantly decreased versus baseline, with mean regurgitant volume decreased from 50.3 to 27.5 ml (change -22.8 ml; p <0.0001), regurgitant fraction from 44.6% to 28.9% (change -15.7%; p <0.0001), color flow grade from an average of 3.4 to 1.8 (change -1.6; p <0.0001), and pulmonary vein flow from 2.8 to 1.8 (change -1.0; p <0.0018). In conclusion, quantitative assessment of MR is feasible in a multicenter trial, and percutaneous mitral repair with the MitraClip produces a sustained decrease in MR severity to moderate or less for > or =6 months.
Similar articles
-
Extended use of percutaneous edge-to-edge mitral valve repair beyond EVEREST (Endovascular Valve Edge-to-Edge Repair) criteria: 30-day and 12-month clinical and echocardiographic outcomes from the GRASP (Getting Reduction of Mitral Insufficiency by Percutaneous Clip Implantation) registry.JACC Cardiovasc Interv. 2015 Jan;8(1 Pt A):74-82. doi: 10.1016/j.jcin.2014.07.024. Epub 2014 Dec 10. JACC Cardiovasc Interv. 2015. PMID: 25499300
-
Quantification of mitral regurgitation by real time three-dimensional color Doppler flow echocardiography pre- and post-percutaneous mitral valve repair.Echocardiography. 2015 Jul;32(7):1140-6. doi: 10.1111/echo.12809. Epub 2014 Oct 18. Echocardiography. 2015. PMID: 25327820
-
Analysis of procedural effects of percutaneous edge-to-edge mitral valve repair by 2D and 3D echocardiography.Circ Cardiovasc Imaging. 2012 Nov;5(6):748-55. doi: 10.1161/CIRCIMAGING.112.974691. Epub 2012 Sep 21. Circ Cardiovasc Imaging. 2012. PMID: 23001897
-
Color flow imaging of the vena contracta in mitral regurgitation: technical considerations.J Am Soc Echocardiogr. 2003 Sep;16(9):1002-6. doi: 10.1016/S0894-7317(03)00509-1. J Am Soc Echocardiogr. 2003. PMID: 12931115 Review.
-
[Calculation of the regurgitation fraction in mitral insufficiency by Doppler echocardiography using a study of the zone of flow convergence].Arch Mal Coeur Vaiss. 1997 Jan;90(1):17-25. Arch Mal Coeur Vaiss. 1997. PMID: 9137711 Review. French.
Cited by
-
Conventional echocardiographic parameters or three-dimensional echocardiography to evaluate right ventricular function in percutaneous edge-to-edge mitral valve repair (PMVR).Int J Cardiol Heart Vasc. 2019 Aug 30;24:100413. doi: 10.1016/j.ijcha.2019.100413. eCollection 2019 Sep. Int J Cardiol Heart Vasc. 2019. PMID: 31508480 Free PMC article.
-
Immediate Post-Procedural and Discharge Assessment of Mitral Valve Function Following Transcatheter Edge-to-Edge Mitral Valve Repair: Correlation and Association with Outcomes.J Clin Med. 2021 Nov 22;10(22):5448. doi: 10.3390/jcm10225448. J Clin Med. 2021. PMID: 34830731 Free PMC article.
-
Quantitation of mitral regurgitation after percutaneous MitraClip repair: comparison of Doppler echocardiography and cardiac magnetic resonance imaging.Ann Cardiothorac Surg. 2015 Jul;4(4):341-51. doi: 10.3978/j.issn.2225-319X.2015.05.03. Ann Cardiothorac Surg. 2015. PMID: 26309843 Free PMC article.
-
Comprehensive echocardiographic prediction of postprocedural transmitral pressure gradient following transcatheter mitral valve repair.Int J Cardiovasc Imaging. 2021 Oct;37(10):2947-2955. doi: 10.1007/s10554-021-02290-4. Epub 2021 May 27. Int J Cardiovasc Imaging. 2021. PMID: 34046774
-
3D echocardiography in mitral valve prolapse.Front Cardiovasc Med. 2023 Jan 10;9:1050476. doi: 10.3389/fcvm.2022.1050476. eCollection 2022. Front Cardiovasc Med. 2023. PMID: 36704460 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources