Measuring dynamic in-vivo glenohumeral joint kinematics: technique and preliminary results
- PMID: 17996874
- PMCID: PMC2288548
- DOI: 10.1016/j.jbiomech.2007.09.029
Measuring dynamic in-vivo glenohumeral joint kinematics: technique and preliminary results
Abstract
Rotator cuff tears are a common injury that affect a significant percentage of the population over age 60. Although it is widely believed that the rotator cuff's primary function is to stabilize the humerus against the glenoid during shoulder motion, accurately measuring the three-dimensional (3D) motion of the shoulder's glenohumeral joint under in-vivo conditions has been a challenging endeavor. In particular, conventional motion measurement techniques have frequently been limited to static or two-dimensional (2D) analyses, and have suffered from limited or unknown in-vivo accuracy. We have recently developed and validated a new model-based tracking technique that is capable of accurately measuring the 3D position and orientation of the scapula and humerus from biplane X-ray images. Herein we demonstrate the in-vivo application of this technique for accurately measuring glenohumeral joint translations during shoulder motion in the repaired and contralateral shoulders of patients following rotator cuff repair. Five male subjects were tested at 3-4 months following arthroscopic rotator cuff repair. Superior-inferior humeral translation was measured during elevation, and anterior-posterior humeral translation was measured during external rotation in both the repaired and contralateral shoulders. The data failed to detect statistically significant differences between the repaired and contralateral shoulders in superior-inferior translation (p=0.74) or anterior-posterior translation (p=0.77). The measurement technique overcomes the limitations of conventional motion measurement techniques by providing accurate, 3D, in-vivo measures of glenohumeral joint motion during dynamic activities. On-going research is using this technique to assess the effects of conservative and surgical treatment of rotator cuff tears.
Figures



References
-
- Baeyens JP, Van Roy P, De Schepper A, Declercq G, Clarijs JP. Glenohumeral joint kinematics related to minor anterior instability of the shoulder at the end of the late preparatory phase of throwing. Clin Biomech (Bristol, Avon) 2001;16(9):752–7. - PubMed
-
- Graichen H, Hinterwimmer S, von Eisenhart-Rothe R, Vogl T, Englmeier KH, Eckstein F. Effect of abducting and adducting muscle activity on glenohumeral translation, scapular kinematics and subacromial space width in vivo. J Biomech. 2005;38(4):755–60. - PubMed
-
- Graichen H, Stammberger T, Bonel H, Karl-Hans E, Reiser M, Eckstein F. Glenohumeral translation during active and passive elevation of the shoulder - a 3D open-MRI study. J Biomech. 2000;33(5):609–13. - PubMed
-
- Karduna AR, McClure PW, Michener LA, Sennett B. Dynamic measurements of three-dimensional scapular kinematics: a validation study. J Biomech Eng. 2001;123(2):184–90. - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources