Viral clearance studies on new and used chromatography resins: critical review of a large dataset
- PMID: 17997110
- DOI: 10.1016/j.biologicals.2007.08.001
Viral clearance studies on new and used chromatography resins: critical review of a large dataset
Abstract
Viral clearance studies for naïve and maximally cycled chromatographic resins used for cGMP recombinant protein production are reviewed for three products, comprising 10 different chromatographic steps, including affinity, ion exchange, immobilized metal ion affinity, and hydrophobic interaction modes. Thirty-two separate studies were conducted (over 90 runs in total). No consistent reductions in model virus clearance were observed with used resins. The results address the reproducibility of virus clearance studies conducted by different scientists over several years at multiple contract labs. The log reduction values (LRVs) are typically within 0.5 LRVs for new and used resin, but varied as much as 2 LRVs for resins showing no functional deterioration. This relatively large difference is not believed to reflect resin changes, but highlights the challenges encountered in modeling column clearance. Production column performance and cleaning efficacy are demonstrated for these steps by trending mock runs, impurity removal and product recovery. No deterioration in cGMP column performance is seen over the established resin lifetimes, confirming that the resin regeneration and sanitization procedures restore the resins to a suitable initial state without damage. It is proposed that for some chromatography steps, the combination of lab-scale cycling studies confirming consistent performance throughout the resin lifetime and monitoring of cGMP manufacturing preclude the need for virus clearance studies on maximally cycled resin.
Similar articles
-
Retrospective Evaluation of Cycled Resin in Viral Clearance Studies-A Multiple Company Collaboration.PDA J Pharm Sci Technol. 2019 Sep-Oct;73(5):470-486. doi: 10.5731/pdajpst.2018.009605. Epub 2019 May 17. PDA J Pharm Sci Technol. 2019. PMID: 31101706
-
High-throughput screening of chromatographic separations: I. Method development and column modeling.Biotechnol Bioeng. 2008 Jul 1;100(4):605-18. doi: 10.1002/bit.21904. Biotechnol Bioeng. 2008. PMID: 18496874
-
A mechanistic study of Protein A chromatography resin lifetime.J Chromatogr A. 2009 Jul 31;1216(31):5849-55. doi: 10.1016/j.chroma.2009.06.013. Epub 2009 Jun 10. J Chromatogr A. 2009. PMID: 19539295
-
Chromatographic removal of viruses from plasma derivatives.Dev Biol Stand. 1993;81:199-209. Dev Biol Stand. 1993. PMID: 8174804 Review.
-
Pathogen safety of intravenous Rh immunoglobulin liquid and other immune globulin products: enhanced nanofiltration and manufacturing process overview.Am J Ther. 2008 Sep-Oct;15(5):435-43. doi: 10.1097/MJT.0b013e318160c1b7. Am J Ther. 2008. PMID: 18806519 Review.
Cited by
-
Downstream Processing Technologies/Capturing and Final Purification : Opportunities for Innovation, Change, and Improvement. A Review of Downstream Processing Developments in Protein Purification.Adv Biochem Eng Biotechnol. 2018;165:115-178. doi: 10.1007/10_2017_12. Adv Biochem Eng Biotechnol. 2018. PMID: 28795201 Review.
-
Polysaccharide-based chromatographic adsorbents for virus purification and viral clearance.J Pharm Anal. 2020 Aug;10(4):291-312. doi: 10.1016/j.jpha.2020.01.002. Epub 2020 Jan 13. J Pharm Anal. 2020. PMID: 32292625 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous