What biomechanical properties of the cornea are relevant for the clinician?
- PMID: 17998034
- DOI: 10.1016/j.survophthal.2007.08.004
What biomechanical properties of the cornea are relevant for the clinician?
Abstract
Although the effects of central corneal thickness and corneal curvature on intraocular pressure measurement are well known, it has only recently become possible to measure the biomechanical properties of the cornea in vivo. This article reviews the structural and material properties of the cornea and considers the effects of corneal parameters, including biomechanics, on IOP measurement. The role of corneal biomechanics as a potential indicator of the structural integrity of the globe will also be discussed. Current evidence suggests that the importance of corneal biomechanics to the glaucoma clinician rests primarily with its effects on IOP measurement. However, the possibility that corneal biomechanics may give an indication of the structural integrity of the optic nerve head cannot be completely excluded. Further population and longitudinal studies are needed to clarify whether current in vivo measures of corneal biomechanical properties, including corneal hysteresis, prove to be independent predictors of glaucoma susceptibility.
Similar articles
-
Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis.J Cataract Refract Surg. 2005 Jan;31(1):146-55. doi: 10.1016/j.jcrs.2004.09.031. J Cataract Refract Surg. 2005. PMID: 15721707
-
Intraocular pressure and central corneal thickness.Prog Brain Res. 2008;173:25-30. doi: 10.1016/S0079-6123(08)01103-5. Prog Brain Res. 2008. PMID: 18929099 Review.
-
Effect of central corneal thickness and corneal hysteresis on tonometry as measured by dynamic contour tonometry, ocular response analyzer, and Goldmann tonometry in glaucomatous eyes.J Glaucoma. 2008 Aug;17(5):361-5. doi: 10.1097/IJG.0b013e31815c3ad3. J Glaucoma. 2008. PMID: 18703945
-
Effect of aging on corneal biomechanical parameters using the ocular response analyzer.J Refract Surg. 2009 Oct;25(10):888-93. doi: 10.3928/1081597X-20090917-10. Epub 2009 Oct 12. J Refract Surg. 2009. PMID: 19835329
-
New ways to measure intraocular pressure.Curr Opin Ophthalmol. 2008 Mar;19(2):122-6. doi: 10.1097/ICU.0b013e3282f391ae. Curr Opin Ophthalmol. 2008. PMID: 18301285 Review.
Cited by
-
Corneal biomechanical changes and intraocular pressure in patients with thyroid orbitopathy.Int J Ophthalmol. 2016 Mar 18;9(3):439-43. doi: 10.18240/ijo.2016.03.20. eCollection 2016. Int J Ophthalmol. 2016. PMID: 27158617 Free PMC article.
-
Rate of central corneal thickness changes in primary angle closure eyes: long-term follow-up results.BMC Ophthalmol. 2021 Mar 22;21(1):145. doi: 10.1186/s12886-021-01908-4. BMC Ophthalmol. 2021. PMID: 33752630 Free PMC article.
-
Anterior and posterior corneal stroma elasticity assessed using nanoindentation.Exp Eye Res. 2013 Oct;115:41-6. doi: 10.1016/j.exer.2013.06.004. Epub 2013 Jun 22. Exp Eye Res. 2013. PMID: 23800511 Free PMC article.
-
Biomechanical evaluation of cornea in patients with ankylosing spondylitis.Int Ophthalmol. 2017 Aug;37(4):1017-1024. doi: 10.1007/s10792-016-0368-3. Epub 2016 Oct 5. Int Ophthalmol. 2017. PMID: 27709370
-
Acoustic Micro-Tapping Optical Coherence Elastography to Quantify Corneal Collagen Cross-Linking: An Ex Vivo Human Study.Ophthalmol Sci. 2022 Nov 13;3(2):100257. doi: 10.1016/j.xops.2022.100257. eCollection 2023 Jun. Ophthalmol Sci. 2022. PMID: 36685713 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources