Advantages of multiple algorithm support in treatment planning system for external beam dose calculations
- PMID: 17998620
- DOI: 10.4103/0973-1482.16085
Advantages of multiple algorithm support in treatment planning system for external beam dose calculations
Abstract
The complexity of interactions and the nature of the approximations made in the formulation of the algorithm require that the user be familiar with the limitations of various models. As computer power keeps growing, calculation algorithms are tending more towards physically based models. The nature and quantity of the data required varies according to the model which may be either measurement based models or physical based models. Multiple dose calculation algorithm support found in XiO Treatment Planning System can be used to advantage when choice is to be made between speed and accuracy. Thus XiO allows end users generate plans accurately and quickly to optimize the delivery of radiation therapy.
Similar articles
-
An algorithm to assess the need for clinical Monte Carlo dose calculation for small proton therapy fields based on quantification of tissue heterogeneity.Med Phys. 2013 Aug;40(8):081704. doi: 10.1118/1.4812682. Med Phys. 2013. PMID: 23927301
-
Impact of grid size on uniform scanning and IMPT plans in XiO treatment planning system for brain cancer.J Appl Clin Med Phys. 2015 Sep 8;16(5):447–456. doi: 10.1120/jacmp.v16i5.5510. J Appl Clin Med Phys. 2015. PMID: 26699310 Free PMC article.
-
Clinical implementation of full Monte Carlo dose calculation in proton beam therapy.Phys Med Biol. 2008 Sep 7;53(17):4825-53. doi: 10.1088/0031-9155/53/17/023. Epub 2008 Aug 13. Phys Med Biol. 2008. PMID: 18701772
-
Optimized planning using physical objectives and constraints.Semin Radiat Oncol. 1999 Jan;9(1):20-34. doi: 10.1016/s1053-4296(99)80052-6. Semin Radiat Oncol. 1999. PMID: 10196396 Review.
-
Monte Carlo systems used for treatment planning and dose verification.Strahlenther Onkol. 2017 Apr;193(4):243-259. doi: 10.1007/s00066-016-1075-8. Epub 2016 Nov 25. Strahlenther Onkol. 2017. PMID: 27888282 Review. English.
Cited by
-
Optimization of Clarkson's Method for Calculating Absorbed Dose under Compensator Filters used in Intensity-modulated Radiation Therapy.J Biomed Phys Eng. 2020 Oct 1;10(5):575-582. doi: 10.31661/jbpe.v0i0.858. eCollection 2020 Oct. J Biomed Phys Eng. 2020. PMID: 33134216 Free PMC article.
-
Performance Evaluation of Algorithms in Lung IMRT: A comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms.J Biomed Phys Eng. 2016 Sep 1;6(3):127-138. eCollection 2016 Sep. J Biomed Phys Eng. 2016. PMID: 27853720 Free PMC article.
-
Dosimetric Comparison of Different Dose Calculation Algorithms in Postmastectomy Breast Cancer Patients Using Conformal Planning Techniques.J Med Phys. 2023 Apr-Jun;48(2):136-145. doi: 10.4103/jmp.jmp_28_23. Epub 2023 Jun 29. J Med Phys. 2023. PMID: 37576097 Free PMC article.
-
Point Dose Measurement for Verification of Treatment Planning System using an Indigenous Heterogeneous Pelvis Phantom for Clarkson, Convolution, Superposition, and Fast Superposition Algorithms.J Biomed Phys Eng. 2019 Dec 1;9(6):613-620. doi: 10.31661/jbpe.v0i0.1185. eCollection 2019 Dec. J Biomed Phys Eng. 2019. PMID: 32039091 Free PMC article.
-
Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system.J Med Phys. 2009 Jan;34(1):12-22. doi: 10.4103/0971-6203.48716. J Med Phys. 2009. PMID: 20126561 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials