Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions
- PMID: 17999036
- DOI: 10.1007/s10856-007-3138-y
Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions
Abstract
Titanium and cobalt alloys, as well as some stainless steels, are among the most frequently used materials in orthopaedic surgery. In industrialized countries, stainless steel devices are used only for temporary implants due to their lower corrosion resistance in physiologic media when compared to other alloys. However, due to economical reasons, the use of stainless steel alloys for permanent implants is very common in developing countries. The implantation of foreign bodies is sometimes necessary in the modern medical practice. However, the complex interactions between the host and the can implant weaken the local immune system, increasing the risk of infections. Therefore, it is necessary to further study these materials as well as the characteristics of the superficial film formed in physiologic media in infection conditions in order to control their potential toxicity due to the release of metallic ions in the human body. This work presents a study of the superficial composition and the corrosion resistance of AISI 316L stainless steel and the influence of its main alloying elements when they are exposed to an acidic solution that simulates the change of pH that occurs when an infection develops. Aerated simulated body fluid (SBF) was employed as working solution at 37 degrees C. The pH was adjusted to 7.25 and 4 in order to reproduce normal body and disease state respectively. Corrosion resistance was measured by means of electrochemical impedance spectroscopy (EIS) and anodic polarization curves.
Similar articles
-
A comparative study of the in vitro corrosion behavior and cytotoxicity of a superferritic stainless steel, a Ti-13Nb-13Zr alloy, and an austenitic stainless steel in Hank's solution.J Biomed Mater Res B Appl Biomater. 2005 Apr;73(1):109-16. doi: 10.1002/jbm.b.30205. J Biomed Mater Res B Appl Biomater. 2005. PMID: 15660438
-
In vitro corrosion behavior of bioceramic, metallic, and bioceramic-metallic coated stainless steel dental implants.Dent Mater. 2003 May;19(3):188-98. doi: 10.1016/s0109-5641(02)00029-5. Dent Mater. 2003. PMID: 12628430
-
Corrosion behavior of 2205 duplex stainless steel.Am J Orthod Dentofacial Orthop. 1997 Jul;112(1):69-79. doi: 10.1016/s0889-5406(97)70276-2. Am J Orthod Dentofacial Orthop. 1997. PMID: 9228844
-
Electrochemical corrosion of metallic biomaterials.Biomaterials. 1984 May;5(3):122-34. doi: 10.1016/0142-9612(84)90046-2. Biomaterials. 1984. PMID: 6375748 Review.
-
A review on nickel-free nitrogen containing austenitic stainless steels for biomedical applications.Mater Sci Eng C Mater Biol Appl. 2013 Oct;33(7):3563-75. doi: 10.1016/j.msec.2013.06.002. Epub 2013 Jun 12. Mater Sci Eng C Mater Biol Appl. 2013. PMID: 23910251 Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources