Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Jan;36(1):166-71.
doi: 10.1097/01.CCM.0000297886.32564.CF.

C-reactive protein correlates with bacterial load and appropriate antibiotic therapy in suspected ventilator-associated pneumonia

Affiliations

C-reactive protein correlates with bacterial load and appropriate antibiotic therapy in suspected ventilator-associated pneumonia

Thiago Lisboa et al. Crit Care Med. 2008 Jan.

Abstract

Objective: Appropriateness of antibiotic therapy is associated with reduction of bacterial load in ventilator-associated pneumonia. C-reactive protein is a valid biochemical surrogate. The objective was to determine the correlation of bacterial load, measured by quantitative tracheal aspirate (QTA), with serum C-reactive protein as an indicator of inflammatory response in episodes of ventilator-associated pneumonia and association of its variation with antibiotic appropriateness.

Design: Prospective, observational cohort study.

Setting: Two medical-surgical intensive care units at large urban hospitals affiliated with teaching institutions.

Patients: Sixty-eight intubated patients with monomicrobial ventilator-associated pneumonia.

Interventions: None.

Measurements and main results: QTA and serum C-reactive protein were measured in patients with suspected ventilator-associated pneumonia on diagnosis (baseline) and 96 hrs afterward (follow-up). Its logarithm value (logQTA) was calculated. LogQTA correlated positively with serum C-reactive protein (rho = 0.46, p < .05), temperature (rho = 0.20, p = .05), and white blood cell count (rho = 0.22, p < .05). LogQTA decreased significantly more from baseline to follow-up in patients receiving appropriate empirical antibiotic therapy compared with those with inappropriate treatment (logQTA ratio 0.77 +/- 0.22 vs. 1.02 +/- 0.27, p < .05). Mean serum C-reactive protein levels showed a similar pattern, decreasing from baseline to follow-up in patients receiving appropriate empirical antibiotic treatment but not in episodes with inappropriate treatment (C-reactive protein ratio 0.58 +/- 0.32 vs. 1.36 +/- 1.11, p < .05). There was a positive correlation between serum C-reactive protein and logQTA variations (r2 = .59, p < .05). Adjusted mean serum C-reactive protein levels by analysis of covariance on follow-up were significantly lower in patients with appropriate antibiotic treatment than in those with inappropriate empirical treatment (103 +/- 10 mg/L vs. 192 +/- 14 mg/L, p < .05). A C-reactive protein ratio of 0.8 at 96 hrs was a useful indicator of appropriateness of antibiotic therapy (sensitivity 77%; specificity 87%; area under the receiver operating characteristic curve 0.86 [0.75-0.96]).

Conclusions: C-reactive protein is a useful biochemical surrogate of bacterial burden in patients with ventilator-associated pneumonia. Follow-up measurements of serum C-reactive protein anticipate the appropriateness of antibiotic therapy.

PubMed Disclaimer

Publication types