Assist devices fail to reverse patterns of fetal gene expression despite beta-blockers
- PMID: 18022084
- PMCID: PMC2768343
- DOI: 10.1016/j.healun.2007.08.003
Assist devices fail to reverse patterns of fetal gene expression despite beta-blockers
Abstract
Background: Heart failure is associated with reversal to a fetal gene expression pattern of contractile and metabolic genes. Substantial recovery of ventricular function with assist devices is rare. Our goal was to evaluate the effects of assist devices on fetal gene expression and hypoxia inducible factor-1 alpha (HIF-1 alpha), a transcriptional factor in hypoxic signaling.
Methods: Human heart tissue was obtained from the left ventricular apex at the time of assist device implantation and again from the left ventricular free wall during cardiac transplantation. Non-failing tissue was obtained from unused hearts from human donors. Gene expression was measured with the Affymetrix 133 plus 2 Array. HIF-1 alpha was measured by Western blotting with commercially available antibodies.
Results: Heart failure was associated with a decrease in alpha-myosin heavy chain and sarcoplasmic reticulum-Ca(2+) adenosine triphosphatase messenger RNA expression along with an increase in skeletal tropomyosin. This pattern persisted after assist device therapy. Heart failure was also associated with abnormalities in regulatory metabolic genes including glucose transporter 1 (GLUT1). These patterns also persisted after assist device therapy despite a reduction in atrial natriuretic peptide expression and normalization of HIF-1 alpha.
Conclusions: Failure of assist devices to produce sustained recovery of myocardial contractile function may be due in part to persistent fetal transcriptional patterns of contractile and metabolic genes.
Figures
References
-
- Rose EA, Gelijns AC, Moskowitz AJ, Heitjan DF, Stevenson LW, Dembitsky W, Long JW, Ascheim DD, Tierney AR, Levitan RG, Watson JT, Ronan NS, Shapiro PA, Lazar RM, Miller LW, Gupta L, Frazier OH, Desvigne-Nickens P, Oz MC, Poirier VL, Meier P. The Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group, Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure. N Engl J Med. 2001;345:1435–1443. - PubMed
-
- Long JW, Kfoury AG, Slaughter MS, Silver M, Milano C, Rogers J, Delgado R, Frazier OH. Long-term destination therapy with the HeartMate XVE left ventricular assist device: improved outcomes since the REMATCH study. Congestive Heart Failure. 2005;11(3):133–8. - PubMed
-
- Nakatani S, McCarthy PM, Kottke-Marchant K, Harasaki H, James KB, Savage RM, Thomas JD. Left ventricular echocardiographic and histologic changes: impact of chronic unloading by an implantable ventricular assist device. Journal of the American College of Cardiology. 1996;27(4):894–901. - PubMed
-
- Muller J, Wallukat G, Weng YG, Dandel M, Spiegelsberger S, Semrau S, Brandes K, Theodoridis V, Loebe M, Meyer R, Hetzer R. Weaning from mechanical cardiac support in patients with idiopathic dilated cardiomyopathy. Circulation. 1997;96(2):542–9. - PubMed
-
- Mancini D, Goldsmith R, Levin H, Beniaminovitz A, Rose E, Catanese K, Flannery M, Oz M. Comparison of exercise performance in patients with chronic severe heart failure versus left ventricular assist devices. Circulation. 1998;98(12):1178–83. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources