Pulsatile perfusion during cardiopulmonary bypass procedures in neonates, infants, and small children
- PMID: 18043152
- DOI: 10.1097/MAT.0b013e318158e3f9
Pulsatile perfusion during cardiopulmonary bypass procedures in neonates, infants, and small children
Abstract
Multiple factors influence the outcome of cardiopulmonary bypass (CPB) procedures in pediatric patients with congenital heart defects. The benefit of pulsatile over nonpulsatile perfusion is one such factor that continues to be widely debated among researchers, perfusionists, and surgeons. However, by accurately measuring pulsatile flow in terms of energy equivalent pressure and surplus hemodynamic energy, pulsatile perfusion is clearly seen to replicate the physiologic heart in a manner unparalleled by nonpulsatile perfusion. Studied benefits of pulsatile perfusion in pediatric patients include increased vital organ blood flow and improvement in postoperative recovery. Also, the components of the extracorporeal circuit used in CPB are directly related to pulsatility and have a profound effect on hemodynamics in the circuit and the patient. Therefore, pulsatility and surplus hemodynamic energy delivery to the patient can be maximized by choosing the best performing heart-pumps, oxygenators, arterial filters, and cannulae. Furthermore, in using the most optimal circuit components available, the CPB procedure under pulsatile perfusion can proceed efficiently. Currently, the outcomes resulting from pulsatile perfusion in pediatric and adult patients, as well as animal models, are well documented. However, more multilaboratory efforts are necessary to understand and further validate the benefits of pulsatile perfusion in pediatric patients.
Similar articles
-
An evaluation of the benefits of pulsatile versus nonpulsatile perfusion during cardiopulmonary bypass procedures in pediatric and adult cardiac patients.ASAIO J. 2006 Jul-Aug;52(4):357-61. doi: 10.1097/01.mat.0000225266.80021.9b. ASAIO J. 2006. PMID: 16883112 Review.
-
Quantification of perfusion modes in terms of surplus hemodynamic energy levels in a simulated pediatric CPB model.ASAIO J. 2006 Nov-Dec;52(6):712-7. doi: 10.1097/01.mat.0000249013.15237.5e. ASAIO J. 2006. PMID: 17117064
-
Optimizing the circuit of a pulsatile extracorporeal life support system in terms of energy equivalent pressure and surplus hemodynamic energy.Artif Organs. 2009 Nov;33(11):1015-20. doi: 10.1111/j.1525-1594.2009.00887.x. Epub 2009 Oct 22. Artif Organs. 2009. PMID: 19849687
-
Comparison of four different pediatric 10F aortic cannulae during pulsatile versus nonpulsatile perfusion in a simulated neonatal model of cardiopulmonary bypass.ASAIO J. 2007 Nov-Dec;53(6):778-84. doi: 10.1097/MAT.0b013e31815b0cd7. ASAIO J. 2007. PMID: 18043165
-
Optimal perfusion during cardiopulmonary bypass: an evidence-based approach.Anesth Analg. 2009 May;108(5):1394-417. doi: 10.1213/ane.0b013e3181875e2e. Anesth Analg. 2009. PMID: 19372313 Review.
Cited by
-
International conference on pediatric mechanical circulatory support systems and pediatric cardiopulmonary perfusion: outcomes and future directions.ASAIO J. 2008 Mar-Apr;54(2):141-6. doi: 10.1097/MAT.0b013e318167afdd. ASAIO J. 2008. PMID: 18356645 Free PMC article. No abstract available.
-
Cardiopulmonary bypass associated acute kidney injury: better understanding and better prevention.Ren Fail. 2024 Dec;46(1):2331062. doi: 10.1080/0886022X.2024.2331062. Epub 2024 Mar 21. Ren Fail. 2024. PMID: 38515271 Free PMC article. Review.
-
Shear stress, energy losses, and costs: a resolved dilemma of pulsatile cardiac assist devices.Biomed Res Int. 2014;2014:651769. doi: 10.1155/2014/651769. Epub 2014 Jan 8. Biomed Res Int. 2014. PMID: 24511541 Free PMC article.
-
Preclinical Proof-of-Concept of a Minimally Invasive Direct Cardiac Compression Device for Pediatric Heart Support.Cardiovasc Eng Technol. 2024 Apr;15(2):147-158. doi: 10.1007/s13239-023-00703-0. Epub 2023 Dec 18. Cardiovasc Eng Technol. 2024. PMID: 38110762 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources