Towards subject-specific models of the dynamic heart for image-guided mitral valve surgery
- PMID: 18044557
- DOI: 10.1007/978-3-540-75759-7_12
Towards subject-specific models of the dynamic heart for image-guided mitral valve surgery
Abstract
Surgeons need a robust interventional system capable of providing reliable, real-time information regarding the position and orientation of the surgical targets and tools to compensate for the lack of direct vision and to enhance manipulation of intracardiac targets during minimally-invasive, off-pump cardiac interventions. In this paper, we describe a novel method for creating dynamic, pre-operative, subject-specific cardiac models containing the surgical targets and surrounding anatomy, and how they are used to augment the intra-operative virtual environment for guidance of valvular interventions. The accuracy of these pre-operative models was established by comparing the target registration error between the mitral valve annulus characterized in the pre-operative images and their equivalent structures manually extracted from 3D US data. On average, the mitral valve annulus was extracted with a 3.1 mm error across all cardiac phases. In addition, we also propose a method for registering the pre-operative models into the intra-operative virtual environment.
Similar articles
-
A review of 3D/2D registration methods for image-guided interventions.Med Image Anal. 2012 Apr;16(3):642-61. doi: 10.1016/j.media.2010.03.005. Epub 2010 Apr 13. Med Image Anal. 2012. PMID: 20452269 Review.
-
Image guidance of intracardiac ultrasound with fusion of pre-operative images.Med Image Comput Comput Assist Interv. 2007;10(Pt 1):60-7. doi: 10.1007/978-3-540-75757-3_8. Med Image Comput Comput Assist Interv. 2007. PMID: 18051044
-
A mitral annulus tracking approach for navigation of off-pump beating heart mitral valve repair.Med Phys. 2015 Jan;42(1):456-68. doi: 10.1118/1.4904022. Med Phys. 2015. PMID: 25563285
-
3D Physics-Based Registration of 2D Dynamic MRI Data.Stud Health Technol Inform. 2016;220:432-8. Stud Health Technol Inform. 2016. PMID: 27046618
-
Hybrid surgical guidance based on the integration of radionuclear and optical technologies.Br J Radiol. 2016 Jun;89(1062):20150797. doi: 10.1259/bjr.20150797. Epub 2016 Mar 4. Br J Radiol. 2016. PMID: 26943463 Free PMC article. Review.
Cited by
-
Accuracy considerations in image-guided cardiac interventions: experience and lessons learned.Int J Comput Assist Radiol Surg. 2012 Jan;7(1):13-25. doi: 10.1007/s11548-011-0621-1. Epub 2011 Jun 14. Int J Comput Assist Radiol Surg. 2012. PMID: 21671097 Free PMC article.
-
Inside the beating heart: an in vivo feasibility study on fusing pre- and intra-operative imaging for minimally invasive therapy.Int J Comput Assist Radiol Surg. 2009 Mar;4(2):113-23. doi: 10.1007/s11548-008-0278-6. Epub 2008 Nov 15. Int J Comput Assist Radiol Surg. 2009. PMID: 20033609
-
An Overview on Image Registration Techniques for Cardiac Diagnosis and Treatment.Cardiol Res Pract. 2018 Aug 8;2018:1437125. doi: 10.1155/2018/1437125. eCollection 2018. Cardiol Res Pract. 2018. PMID: 30159169 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Medical