Evaluation of curing light distance on resin composite microhardness and polymerization
- PMID: 18051007
- DOI: 10.2341/06-163
Evaluation of curing light distance on resin composite microhardness and polymerization
Abstract
This study evaluated the influence of the curing tip distance on cure depth of a resin composite by measuring Vickers microhardness and determining the degree of conversion by using FT-Raman spectroscopy. The light curing units used were halogen (500mW/cm2) and LED (900mW/cm2) at a conventional intensity and an Argon laser at 250mW. The exposure time was 40 seconds for the halogen light, 20 seconds for the LED and 20 and 30 seconds for the Argon laser. The curing tip distances of 0, 3, 6 and 9 mm were used and controlled via the use of metal rings. The composite was placed in a black matrix in one increment at a thickness of 1 mm to 4 mm. The values of microhardness and the degree of conversion were analyzed separately by ANOVA (Analysis of Variance) and Tukey test, with a significance level set at 5%. Correlations were analyzed using the Pearson test. The results obtained conclude that greater tip distances produced a decrease in microhardness and degree of conversion values, while increasing the resin thickness decreased the microhardness and degree of conversion values. A higher correlation between microhardness and the degree of conversion was shown. This study suggests that the current light curing units promote a similar degree of conversion and microhardness, provided that the resin is not thicker than 1 mm and the light source is at a maximum distance of 3 mm from the resin surface.
Similar articles
-
Comparison of composite curing parameters: effects of light source and curing mode on conversion, temperature rise and polymerization shrinkage.Oper Dent. 2006 Mar-Apr;31(2):219-26. doi: 10.2341/05-15. Oper Dent. 2006. PMID: 16827025
-
Early surface microhardness of a resin composite exposed to a pulse-delayed curing exposure: a comparison of a tungsten halogen and a plasma arc lamp, in vitro.Eur J Prosthodont Restor Dent. 2005 Dec;13(4):177-81. Eur J Prosthodont Restor Dent. 2005. PMID: 16411575
-
Microhardness of resin composites polymerized by plasma arc or conventional visible light curing.Oper Dent. 2002 Jan-Feb;27(1):30-7. Oper Dent. 2002. PMID: 11817467
-
Photopolymerization of composite resin using the argon laser.J Can Dent Assoc. 1999 Sep;65(8):447-50. J Can Dent Assoc. 1999. PMID: 10518340 Review.
-
Effect of irradiance from curing units on the microhardness of composite - a systematic review.Evid Based Dent. 2022 Oct 17. doi: 10.1038/s41432-022-0824-z. Online ahead of print. Evid Based Dent. 2022. PMID: 36253517 Review.
Cited by
-
Argon ion laser curing depth effect on a composite resin.Lasers Med Sci. 2011 Jul;26(4):421-5. doi: 10.1007/s10103-010-0785-x. Epub 2010 May 28. Lasers Med Sci. 2011. PMID: 20508961
-
New Resin-Based Bulk-Fill Composites: in vitro Evaluation of Micro-Hardness and Depth of Cure as Infection Risk Indexes.Materials (Basel). 2020 Mar 13;13(6):1308. doi: 10.3390/ma13061308. Materials (Basel). 2020. PMID: 32183115 Free PMC article.
-
Effect of food stimulated liquids and thermocycling on the monomer elution from a nanofilled composite.Open Dent J. 2013 Jul 26;7:62-7. doi: 10.2174/1874210601307010062. eCollection 2013. Open Dent J. 2013. PMID: 23986791 Free PMC article.
-
Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites.Saudi Dent J. 2021 Dec;33(8):1184-1189. doi: 10.1016/j.sdentj.2021.01.003. Epub 2021 Jan 14. Saudi Dent J. 2021. PMID: 34916770 Free PMC article.
-
Distance and protective barrier effects on the composite resin degree of conversion.Contemp Clin Dent. 2013 Apr;4(2):152-5. doi: 10.4103/0976-237X.114845. Contemp Clin Dent. 2013. PMID: 24015001 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources