Analyzer-based x-ray phase-contrast microscopy combining channel-cut and asymmetrically cut crystals
- PMID: 18052481
- DOI: 10.1063/1.2814022
Analyzer-based x-ray phase-contrast microscopy combining channel-cut and asymmetrically cut crystals
Abstract
An analyzer-based x-ray phase-contrast microscopy (ABM) setup combining a standard analyzer-based x-ray phase-contrast imaging (ABI) setup [nondispersive 4-crystal setup (Bonse-Hart setup)] and diffraction by asymmetrically cut crystals is presented here. An attenuation-contrast microscopy setup with conventional x-ray source and asymmetrically cut crystals is first analyzed. Edge-enhanced effects attributed to phase jumps or refraction/total external reflection on the fiber borders were detected. However, the long exposure times and the possibility to achieve high contrast microscopies by using extremely low attenuation-contrast samples motivated us to assemble the ABM setup using a synchrotron source. This setup was found to be useful for low contrast attenuation samples due to the low exposure time, high contrast, and spatial resolution found. Moreover, thanks to the combination with the nondispersive ABI setup, the diffraction-enhanced x-ray imaging algorithm could be applied.
Similar articles
-
Characterization of pyrocarbon coated materials using laboratory based x-ray phase contrast imaging technique.Rev Sci Instrum. 2007 Aug;78(8):083703. doi: 10.1063/1.2772780. Rev Sci Instrum. 2007. PMID: 17764325
-
Design and implementation of a compact low-dose diffraction enhanced medical imaging system.Acad Radiol. 2009 Aug;16(8):911-7. doi: 10.1016/j.acra.2009.02.007. Epub 2009 Apr 17. Acad Radiol. 2009. PMID: 19375952
-
Diffractive-refractive optics: X-ray splitter.J Synchrotron Radiat. 2010 Jan;17(1):129-31. doi: 10.1107/S090904950904240X. Epub 2009 Nov 17. J Synchrotron Radiat. 2010. PMID: 20029121
-
On the use of CCD area detectors for high-resolution specular X-ray reflectivity.J Synchrotron Radiat. 2006 Jul;13(Pt 4):293-303. doi: 10.1107/S0909049506018000. Epub 2006 Jun 15. J Synchrotron Radiat. 2006. PMID: 16799220 Review.
-
Phase recovery and lensless imaging by iterative methods in optical, X-ray and electron diffraction.Philos Trans A Math Phys Eng Sci. 2002 May 15;360(1794):875-95. doi: 10.1098/rsta.2001.0972. Philos Trans A Math Phys Eng Sci. 2002. PMID: 12804284 Review.
Cited by
-
Analyzer-based X-ray phase contrast imaging using the forward-diffracted o-beam in a few-millimetre-thick Bragg-case asymmetrically cut crystal.J Appl Crystallogr. 2025 Apr 25;58(Pt 3):789-795. doi: 10.1107/S1600576725002985. eCollection 2025 Jun 1. J Appl Crystallogr. 2025. PMID: 40475942 Free PMC article.
-
X-ray zooming optics for analyzer-based multi-contrast computed tomography.J Synchrotron Radiat. 2022 May 1;29(Pt 3):787-793. doi: 10.1107/S1600577522001412. Epub 2022 Mar 15. J Synchrotron Radiat. 2022. PMID: 35511011 Free PMC article.
-
Are human peripheral nerves sensitive to X-ray imaging?PLoS One. 2015 Mar 10;10(3):e0116831. doi: 10.1371/journal.pone.0116831. eCollection 2015. PLoS One. 2015. PMID: 25757086 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources