A highly sensitive assay for ritodrine in human serum by hydrophilic interaction chromatography-tandem mass spectrometry
- PMID: 18054846
- DOI: 10.1016/j.jchromb.2007.11.010
A highly sensitive assay for ritodrine in human serum by hydrophilic interaction chromatography-tandem mass spectrometry
Abstract
We developed a sensitive assay for ritodrine (RTD), a beta2-adrenergic agonist, in human serum. This method was based upon the selective and sensitive technique by a tandem mass spectrometry (MS/MS) using a hydrophilic interaction chromatography (HILIC) technique. This method involved a mixed-mode cation-exchange solid-phase extraction of RTD and isoxsuprine, the internal standard (IS), from serum with Waters Oasis MCX cartridges. The detection was made using a Micromass Quattromicro API LC-MS/MS system with electrospray ionization source in positive ion mode. The separation of the analytes was achieved within 4 min on a silica column with a mobile phase of ammonium acetate (10 mM, pH 4.5) and acetonitrile (10:90, v/v). Multiple reaction monitoring was utilized by monitoring 288.2-->121.1 for RTD, 302.2-->107.0 for IS. The calibration curve for RTD was linear over a range of 0.5-1000 ng/mL. When 50 microL serum was used for extraction, the lower limit of quantification was 0.39 ng/mL (97.5 fg on-column). The percent coefficient of validation for accuracy and precision (inter- and intra-day) was less than 9.8% and the recovery was ranged from 83.5 to 94.7% for RTD. This method enabled us to successfully determine RTD in maternal and fetal sera.
Similar articles
-
Development and validation of a selective and sensitive bioanalytical procedure for the quantitative determination of gaboxadol in human plasma employing mixed mode solid phase extraction and hydrophilic interaction liquid chromatography with tandem mass spectroscopic detection.J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Oct 15;858(1-2):168-76. doi: 10.1016/j.jchromb.2007.08.029. Epub 2007 Aug 30. J Chromatogr B Analyt Technol Biomed Life Sci. 2007. PMID: 17851145
-
A simple and rapid determination of valproic acid in human plasma using a non-porous silica column and liquid chromatography with tandem mass spectrometric detection.Biomed Chromatogr. 2008 Apr;22(4):387-93. doi: 10.1002/bmc.944. Biomed Chromatogr. 2008. PMID: 18004739
-
Simultaneous determination of glycyrrhizin, a marker component in radix Glycyrrhizae, and its major metabolite glycyrrhetic acid in human plasma by LC-MS/MS.J Chromatogr B Analyt Technol Biomed Life Sci. 2005 Jan 25;814(2):201-7. doi: 10.1016/j.jchromb.2004.10.026. J Chromatogr B Analyt Technol Biomed Life Sci. 2005. PMID: 15639440
-
Quantification of polar drugs in human plasma with liquid chromatography-tandem mass spectrometry.Bioanalysis. 2009 Apr;1(1):187-203. doi: 10.4155/bio.09.19. Bioanalysis. 2009. PMID: 21083196 Review.
-
Hydrophilic interaction liquid chromatography-tandem mass spectrometry for drug development.Curr Drug Discov Technol. 2010 Sep;7(3):223-31. Curr Drug Discov Technol. 2010. PMID: 20843291 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources