Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Dec;30(12):2360-4.
doi: 10.1248/bpb.30.2360.

Electrophysiological characterization of tight junctional pathway of rabbit cornea treated with ophthalmic ingredients

Affiliations
Free article

Electrophysiological characterization of tight junctional pathway of rabbit cornea treated with ophthalmic ingredients

Tadahiro Nakamura et al. Biol Pharm Bull. 2007 Dec.
Free article

Abstract

The purpose of this study was to investigate the continuous and real-time influence of ophthalmic ingredients on rabbit cornea by monitoring electrophysiological characteristics. The tight junctional permeabilities of FITC-dextran 4,400 (FD-4) was also determined through the cornea in the presence of ophthalmic ingredients. Intact cornea showed approximately one k-ohmxcm(2) of transepithelial electrical resistance (TEER) and extremely low permeability of FD-4. The ophthalmic ingredients used in the present study were benzalkonium chloride (BK; 0.002%, 0.01%, 0.05%), ethylenediaminetetraacetic acid (EDTA; 0.5%), capric acid (C10; 0.25%), saponin (SP; 0.1%), taurocholic acid (TA; 1.0%) and sodium dodecyl sulfate (SDS; 0.01%). They were previously reported to be effective on corneal penetrations of various drugs at those concentrations without severe toxicity. These ingredients decreased TEER and increased corneal permeability of FD-4. BK reduced TEER in a concentration-dependent manner. There was a significant correlation (gamma=0.860) between the permeability coefficient (Papp) of FD-4 and conductance (Gm), which is the reciprocal value of TEER. It was also indicated that Papp and Gm have a relationship with the corneal cytotoxicity of the ingredients. In conclusion, an electrophysiological method using isolated cornea was very useful to determine the continuous and real-time influence of ophthalmic ingredients on the cornea. In this method, electrophysiological conductance must be able to predict corneal tight junction permeability and the corneal cytotoxicity of ingredients.

PubMed Disclaimer