Comparative Study
. 2009 Jan;24(1):87-92.
doi: 10.1007/s10103-007-0527-x. Epub 2007 Dec 5.

Micro-hardness evaluation of a micro-hybrid composite resin light cured with halogen light, light-emitting diode and argon ion laser

Affiliations
Comparative Study

Micro-hardness evaluation of a micro-hybrid composite resin light cured with halogen light, light-emitting diode and argon ion laser

Katia M Rode et al. Lasers Med Sci. 2009 Jan.

Abstract

This in vitro study aimed to determine whether the micro-hardness of a composite resin is modified by the light units or by the thickness of the increment. Composite resin disks were divided into 15 groups (n = 5), according to the factors under study: composite resin thickness (0 mm, 1 mm, 2 mm , 3 mm and 4 mm) and light units. The light activation was performed with halogen light (HL) (40 s, 500 mW/cm(2)), argon ion laser (AL) (30 s, 600 mW/cm(2)) or light-emitting diode (LED) (30 s, 400 mW/cm(2)). Vickers micro-hardness tests were performed after 1 week and were carried out on the top surface (0 mm-control) and at different depths of the samples. Analysis of variance (ANOVA) and Tukey tests (P < or = 0.05) revealed no statistically significant difference among the light units for the groups of 0 mm and 1 mm thickness. At 2 mm depth, the AL was not statistically different from the HL, but the latter showed higher micro-hardness values than the LED. In groups with 3 mm and 4 mm thickness, the HL also showed higher micro-hardness values than the groups activated by the AL and the LED. Only the HL presented satisfactory polymerization with 3 mm of thickness. With a 4 mm increment no light unit was able to promote satisfactory polymerization.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Dent Clin North Am. 2000 Oct;44(4):923-30 - PubMed
    1. Lasers Surg Med. 1991;11(6):495-8 - PubMed
    1. Oper Dent. 1994 Jan-Feb;19(1):26-32 - PubMed
    1. Dent Mater. 2000 Sep;16(5):330-6 - PubMed
    1. Dent Mater. 2005 Jul;21(7):608-15 - PubMed

Publication types

LinkOut - more resources