Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Jul;21(6):598-605.
doi: 10.1002/nbm.1231.

MR measurement of blood flow in the parotid gland without contrast medium: a functional study before and after gustatory stimulation

Affiliations

MR measurement of blood flow in the parotid gland without contrast medium: a functional study before and after gustatory stimulation

Nina F Schwenzer et al. NMR Biomed. 2008 Jul.

Abstract

Purpose: To investigate the feasibility of blood flow imaging in the parotid gland using the arterial spin labeling (ASL) technique for assessment of functional changes in the parotid gland after gustatory stimulation.

Materials and methods: Anatomical and ASL imaging of the parotid gland was performed in eight healthy volunteers before and after gustatory stimulation over a period of 17 min. All measurements were carried out in a 1.5 T whole-body MR unit. ASL and data recording were performed with an adapted FAIR TrueFISP (flow-sensitive alternating inversion-recovery true fast imaging with steady precession) technique. Maps of estimated tissue blood inflow in both parotid glands were derived using a simplified model and the extended Bloch equations.

Results: Delineation of the parotid glands was possible on FAIR TrueFISP images in all cases. In the 160 s period immediately after stimulation, a significant (P < 0.01) mean increase of 62% in the estimated parotid blood flow was observed. Estimated baseline blood flow before gustatory stimulation ranged from 226 to 500 mL/min/100 g (mean +/- SD 335 +/- 86). These rates increased in the 160 s immediately after stimulation to 404-772 mL/min/100 g (mean 542 +/- 108). In all volunteers, blood flow returned to near baseline values within the observation period. No statistically significant difference between the right and left parotid was observed in baseline and peak blood flow.

Conclusion: ASL FAIR TrueFISP is feasible for functional characterization of the parotid glands. Assessment of changes in blood flow in the parotid gland could serve as a diagnostic tool in patients suffering from xerostomia.