CE coupled with amperometric detection using a boron-doped diamond microelectrode: validation of a method for endogenous norepinephrine analysis in tissue
- PMID: 18081202
- DOI: 10.1002/elps.200700398
CE coupled with amperometric detection using a boron-doped diamond microelectrode: validation of a method for endogenous norepinephrine analysis in tissue
Abstract
The level of endogenous norepinephrine (NE) in several tissue types was determined by CE with amperometric detection. We report herein on the method validation by HPLC using both amperometric and coulometric detection (CD). Keys to the method were the use of a diamond microelectrode for detection and off-line SPE for sample preparation. The run buffer was a 250 mM borate solution adjusted to pH 8.8 with potassium hydroxide. The diamond microelectrode exhibited a low and stable background current, and a low peak-to-peak noise < or =0.65 pA at the detection potential of +0.86 V versus Ag/AgCl. For standard solutions, the detector signal (i.e., oxidation current) changed linearly with the NE concentration (r(2) = 0.999) between 60 and 1000 nmol/L with an estimated LOD of 51 nmol/L (S/N = 3) and a response variability of 4.5% (RSD, n = 5). An Oasis MCX sorbent was used for SPE and the procedure produced an NE recovery of 95.1 +/- 5.6% (n = 6) from tissue homogenates. NE levels in the spleen, small intestine, and heart of a normotensive rat were found to be in the range of 0.77-0.97, 0.22-0.32, and 0.29-0.45 microg/g tissue (n = 3), respectively.
Similar articles
-
Determination of endogenous norepinephrine levels in different chambers of the rat heart by capillary electrophoresis coupled with amperometric detection.J Neurosci Methods. 2007 Jun 15;163(1):52-9. doi: 10.1016/j.jneumeth.2007.02.008. Epub 2007 Feb 16. J Neurosci Methods. 2007. PMID: 17383009 Free PMC article.
-
Chlorinated phenol analysis using off-line solid-phase extraction and capillary electrophoresis coupled with amperometric detection and a boron-doped diamond microelectrode.Anal Chem. 2005 Oct 15;77(20):6542-8. doi: 10.1021/ac050473u. Anal Chem. 2005. PMID: 16223238
-
In vitro continuous amperometry with a diamond microelectrode coupled with video microscopy for simultaneously monitoring endogenous norepinephrine and its effect on the contractile response of a rat mesenteric artery.Anal Chem. 2006 Oct 1;78(19):6756-64. doi: 10.1021/ac060440u. Anal Chem. 2006. PMID: 17007494
-
Recent developments in coupled SPE-CE.Electrophoresis. 2010 Jan;31(1):44-54. doi: 10.1002/elps.200900510. Electrophoresis. 2010. PMID: 20014054 Review.
-
Carbon nanotube and diamond as electrochemical detectors in microchip and conventional capillary electrophoresis.Talanta. 2007 Dec 15;74(3):326-32. doi: 10.1016/j.talanta.2007.05.046. Epub 2007 Jun 3. Talanta. 2007. PMID: 18371646 Review.
Cited by
-
Determination of endogenous norepinephrine levels in different chambers of the rat heart by capillary electrophoresis coupled with amperometric detection.J Neurosci Methods. 2007 Jun 15;163(1):52-9. doi: 10.1016/j.jneumeth.2007.02.008. Epub 2007 Feb 16. J Neurosci Methods. 2007. PMID: 17383009 Free PMC article.
-
Boron Doped Diamond Electrodes in Flow-Based Systems.Front Chem. 2019 Apr 3;7:190. doi: 10.3389/fchem.2019.00190. eCollection 2019. Front Chem. 2019. PMID: 31024886 Free PMC article. Review.
-
In Silico Design of a Peptide Receptor for Dopamine Recognition.Molecules. 2020 Nov 25;25(23):5509. doi: 10.3390/molecules25235509. Molecules. 2020. PMID: 33255517 Free PMC article.
-
Recent developments in instrumentation for capillary electrophoresis and microchip-capillary electrophoresis.Electrophoresis. 2010 Aug;31(15):2469-86. doi: 10.1002/elps.201000203. Electrophoresis. 2010. PMID: 20665910 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources