Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume
- PMID: 18082905
- DOI: 10.1016/j.radonc.2007.11.022
Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume
Abstract
Purpose: The purpose of this study was to determine the 4D accumulated dose delivered to the CTV in stereotactic radiotherapy of lung tumours, for treatments planned on an average CT using an ITV derived from the Maximum Intensity Projection (MIP) CT.
Methods: For 10 stage I lung cancer patients, treatment plans were generated based on 4D-CT images. From the 4D-CT scan, 10 time-sorted breathing phases were derived, along with the average CT and the MIP. The ITV with a margin of 0mm was used as a PTV to study a worst case scenario in which the differences between 3D planning and 4D dose accumulation will be largest. Dose calculations were performed on the average CT. Dose prescription was 60Gy to 95% of the PTV, and at least 54Gy should be received by 99% of the PTV. Plans were generated using the inverse planning module of the Pinnacle(3) treatment planning system. The plans consisted of nine coplanar beams with two segments each. After optimisation, the treatment plan was transferred to all breathing phases and the delivered dose per phase was calculated using an elastic body spline model available in our research version of Pinnacle (8.1r). Then, the cumulative dose to the CTV over all breathing phases was calculated and compared to the dose distribution of the original treatment plan.
Results: Although location, tumour size and breathing-induced tumour movement varied widely between patients, the PTV planning criteria could always be achieved without compromising organs at risk criteria. After 4D dose calculations, only very small differences between the initial planned PTV coverage and resulting CTV coverage were observed. For all patients, the dose delivered to 99% of the CTV exceeded 54Gy. For nine out of 10 patients also the criterion was met that the volume of the CTV receiving at least the prescribed dose was more than 95%.
Conclusions: When the target dose is prescribed to the ITV (PTV=ITV) and dose calculations are performed on the average CT, the cumulative CTV dose compares well to the planned dose to the ITV. Thus, the concept of treatment plan optimisation and evaluation based on the average CT and the ITV is a valid approach in stereotactic lung treatment. Even with a zero ITV to PTV margin, no significantly different dose coverage of the CTV arises from the breathing motion induced dose variation over time.
Similar articles
-
Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations.Phys Med Biol. 2006 Jun 7;51(11):2763-79. doi: 10.1088/0031-9155/51/11/006. Epub 2006 May 17. Phys Med Biol. 2006. PMID: 16723765
-
A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy.Radiother Oncol. 2006 Feb;78(2):177-84. doi: 10.1016/j.radonc.2005.11.012. Epub 2006 Jan 10. Radiother Oncol. 2006. PMID: 16376444
-
The use of gated and 4D CT imaging in planning for stereotactic body radiation therapy.Med Dosim. 2007 Summer;32(2):92-101. doi: 10.1016/j.meddos.2007.01.006. Med Dosim. 2007. PMID: 17472888
-
Anatomical imaging for radiotherapy.Phys Med Biol. 2008 Jun 21;53(12):R151-91. doi: 10.1088/0031-9155/53/12/R01. Epub 2008 May 21. Phys Med Biol. 2008. PMID: 18495981 Review.
-
[Target volume margins for lung cancer: internal target volume/clinical target volume].Cancer Radiother. 2013 Oct;17(5-6):428-33. doi: 10.1016/j.canrad.2013.05.008. Epub 2013 Aug 27. Cancer Radiother. 2013. PMID: 23988437 Review. French.
Cited by
-
Impact of the Time Proportion of Respiratory Phases on Dosimetry in SBRT of Lung Tumor Near the Chest Wall or Diaphragm.Technol Cancer Res Treat. 2019 Jan 1;18:1533033819879897. doi: 10.1177/1533033819879897. Technol Cancer Res Treat. 2019. PMID: 31558108 Free PMC article.
-
Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy.Radiat Oncol. 2015 Dec 1;10:249. doi: 10.1186/s13014-015-0557-7. Radiat Oncol. 2015. PMID: 26626865 Free PMC article.
-
Comparison of CT images with average intensity projection, free breathing, and mid-ventilation for dose calculation in lung cancer.J Appl Clin Med Phys. 2017 Mar;18(2):26-36. doi: 10.1002/acm2.12037. Epub 2017 Jan 24. J Appl Clin Med Phys. 2017. PMID: 28300381 Free PMC article.
-
Recommendations for implementing stereotactic radiotherapy in peripheral stage IA non-small cell lung cancer: report from the Quality Assurance Working Party of the randomised phase III ROSEL study.Radiat Oncol. 2009 Jan 12;4:1. doi: 10.1186/1748-717X-4-1. Radiat Oncol. 2009. PMID: 19138400 Free PMC article. Clinical Trial.
-
Impact of Intra-Fractional Motion on Dose Distributions in Lung IMRT.J Radiother Pract. 2021 Mar;20(1):12-16. doi: 10.1017/s1460396919000967. Epub 2020 Jan 9. J Radiother Pract. 2021. PMID: 34168519 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous