Reduction of metal artefacts in musculoskeletal MR imaging
- PMID: 18085188
Reduction of metal artefacts in musculoskeletal MR imaging
Abstract
The purpose of this article is to present a educational overview of practical tips to deal with metal artefacts in clinical musculoskeletal MRI. A brief theoretical explanation to understand the cause of metal artefacts is provided followed by a discussion on parameters to reduce these metal artefacts. Effects of adjustable parameters are demonstrated both in a volunteer with a titanium screw and a saline bag attached to the shoulder and in a in vitro experiment. These parameters include positioning of the patient with the long axis of metallic hardware parallel to B0, use of fast spin echo sequences, use of inversion recovery fat suppression, swapping phase and frequency encoding direction, use of view angle tilting, increasing the read-out bandwidth, and decreasing voxel size.
Similar articles
-
Metal artifact reduction in musculoskeletal magnetic resonance imaging.Orthop Clin North Am. 2006 Jul;37(3):349-59, vi. doi: 10.1016/j.ocl.2006.04.001. Orthop Clin North Am. 2006. PMID: 16846766 Review.
-
Minimizing artifacts caused by metallic implants at MR imaging: experimental and clinical studies.AJR Am J Roentgenol. 1998 Nov;171(5):1207-13. doi: 10.2214/ajr.171.5.9798849. AJR Am J Roentgenol. 1998. PMID: 9798849
-
Optimizing imaging techniques in the postoperative patient.Semin Musculoskelet Radiol. 2007 Sep;11(3):261-72. doi: 10.1055/s-2008-1038315. Semin Musculoskelet Radiol. 2007. PMID: 18260036 Review.
-
Quantitative evaluation of metal artifact reduction techniques.J Magn Reson Imaging. 2004 Sep;20(3):487-95. doi: 10.1002/jmri.20144. J Magn Reson Imaging. 2004. PMID: 15332257
-
MRI susceptibility artefacts related to scaphoid screws: the effect of screw type, screw orientation and imaging parameters.J Hand Surg Br. 2002 Apr;27(2):165-70. doi: 10.1054/jhsb.2001.0717. J Hand Surg Br. 2002. PMID: 12027494
Cited by
-
New MR imaging methods for metallic implants in the knee: artifact correction and clinical impact.J Magn Reson Imaging. 2011 May;33(5):1121-7. doi: 10.1002/jmri.22534. J Magn Reson Imaging. 2011. PMID: 21509870 Free PMC article.
-
Novel MR imaging method--MAVRIC--for metal artifact suppression after joint replacement in musculoskeletal tumor patients.BMC Musculoskelet Disord. 2015 Dec 4;16:377. doi: 10.1186/s12891-015-0838-1. BMC Musculoskelet Disord. 2015. PMID: 26637412 Free PMC article.
-
Comparisons of slice-encoding metal artifact correction and view-angle tilting magnetic resonance imaging and traditional digital radiography in evaluating chronic hip pain after total hip arthroplasty.J Orthop Translat. 2017 Dec 20;12:45-54. doi: 10.1016/j.jot.2017.11.002. eCollection 2018 Jan. J Orthop Translat. 2017. PMID: 29662778 Free PMC article.
-
Osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair.Acta Orthop Traumatol Turc. 2019 Nov;53(6):414-419. doi: 10.1016/j.aott.2019.08.015. Epub 2019 Sep 25. Acta Orthop Traumatol Turc. 2019. PMID: 31563430 Free PMC article.
-
A standardized evaluation of artefacts from metallic compounds during fast MR imaging.Dentomaxillofac Radiol. 2016 Oct;45(8):20160094. doi: 10.1259/dmfr.20160094. Epub 2016 Aug 19. Dentomaxillofac Radiol. 2016. PMID: 27459058 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical