Functional imaging in penile cancer: PET/computed tomography, MRI, and sentinel lymph node biopsy
- PMID: 18090498
- DOI: 10.1097/MOU.0b013e3282f151fd
Functional imaging in penile cancer: PET/computed tomography, MRI, and sentinel lymph node biopsy
Abstract
Purpose of review: The presence and extent of lymph node metastasis and primary tumor are among the most important prognostic factors in penile cancer. While inguinal lymphadenectomy is currently the most accurate means of staging, it is associated with severe morbidity and even mortality. Recent literature was reviewed for alternative means of staging.
Recent findings: Functional imaging modalities distinguish between inguinal lymph nodes with and without metastasis. The false-negative rate of dynamic sentinel lymph node biopsy has recently improved from approximately 20 to 5% in one study. In 13 patients with penile cancer, (18)F-fluorodeoxyglucose-PET/computed tomography was 80% sensitive and 100% specific for lymph node metastasis, but missed micro-metastasis. In seven patients with penile cancer, MRI with lymphotrophic nanoparticles was 100% sensitive and 97% specific for lymph node metastasis.
Summary: Combined PET/computed tomography and sentinel lymph node biopsy may help to detect both inguinal micrometastasis and pelvic and abdominal metastasis. Since MRI is highly accurate for staging of both primary penile cancer and its lymph node metastasis, however, it may turn out to be a powerful tool for a one-stop modality in the staging of penile cancer.
Similar articles
-
Diagnosis and staging of penile cancer.Urology. 2010 Aug;76(2 Suppl 1):S15-23. doi: 10.1016/j.urology.2010.03.002. Urology. 2010. PMID: 20691881 Review.
-
Lymphadenectomy in the surgical management of penile cancer.Eur Urol. 2009 May;55(5):1075-88. doi: 10.1016/j.eururo.2009.02.021. Epub 2009 Feb 23. Eur Urol. 2009. PMID: 19264390 Review.
-
Evaluation of dynamic sentinel lymph node biopsy in patients with squamous cell carcinoma of the penis and palpable inguinal nodes.BJU Int. 2008 Aug;102(3):305-9. doi: 10.1111/j.1464-410X.2008.07628.x. Epub 2008 Apr 11. BJU Int. 2008. PMID: 18410439
-
Size of metastasis in the sentinel node predicts additional nodal involvement in penile carcinoma.J Urol. 2006 Jul;176(1):105-8. doi: 10.1016/S0022-5347(06)00500-3. J Urol. 2006. PMID: 16753383
-
Anatomical mapping of lymphatic drainage in penile carcinoma with SPECT-CT: implications for the extent of inguinal lymph node dissection.Eur Urol. 2008 Oct;54(4):885-90. doi: 10.1016/j.eururo.2008.04.094. Epub 2008 May 19. Eur Urol. 2008. PMID: 18502024
Cited by
-
Value and efficiency of sentinel lymph node diagnostics in patients with penile carcinoma with palpable inguinal lymph nodes as a new multimodal, minimally invasive approach.Eur J Nucl Med Mol Imaging. 2016 Dec;43(13):2313-2323. doi: 10.1007/s00259-016-3482-6. Epub 2016 Aug 12. Eur J Nucl Med Mol Imaging. 2016. PMID: 27519598 Clinical Trial.
-
New histological risk grading system for prediction of lymph node metastasis in patients with penile cancer.Virchows Arch. 2025 Apr;486(4):759-767. doi: 10.1007/s00428-024-03916-3. Epub 2024 Sep 9. Virchows Arch. 2025. PMID: 39251424 Free PMC article.
-
Metastatic penile carcinoma - an update on the current diagnosis and treatment options.Cent European J Urol. 2014;67(2):126-32. doi: 10.5173/ceju.2014.02.art2. Epub 2014 Jun 23. Cent European J Urol. 2014. PMID: 25140224 Free PMC article. Review.
-
Inguinal Lymph Nodes in Carcinoma Penis-Observation or Surgery?J Clin Diagn Res. 2016 Jan;10(1):XC01-XC04. doi: 10.7860/JCDR/2016/15064.7040. Epub 2016 Jan 1. J Clin Diagn Res. 2016. PMID: 26894163 Free PMC article.
-
Upconversion nanophosphors Naluf₄:Yb,Tm for lymphatic imaging in vivo by real-time upconversion luminescence imaging under ambient light and high-resolution X-ray CT.Theranostics. 2013 Apr 23;3(5):346-53. doi: 10.7150/thno.5137. Print 2013. Theranostics. 2013. PMID: 23650481 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials