Comparison of Fick and thermodilution cardiac output determinations in standing horses
- PMID: 18093624
- DOI: 10.1016/j.rvsc.2007.10.013
Comparison of Fick and thermodilution cardiac output determinations in standing horses
Abstract
The Fick and thermodilution (TD) methods are two currently popular techniques for determination of cardiac output (CO) in adult horses. To our knowledge, a comparison of these two techniques has not been reported. Six healthy, resting, fit, adult horses of either sex and weighing 516.5+/-33.2 kg (mean+/-SD) were instrumented to enable measurement of cardiac output. Resting CO was determined by the Fick method and by thermodilution while the horses stood quietly in the stocks. Fick and thermodilution CO measurements were repeated under conditions of increased cardiac output achieved with the use of a dobutamine infusion (5 microg kg(-1) min(-1), IV), and again under conditions of decreased CO induced by administration of xylazine (0.5 mg/kg, IV). Fick and thermodilution cardiac outputs were compared using Bland-Altman analysis for repeated measures. The mean of the differences+/-1.96SD (bias and precision) between the two techniques was 1.88+/-24.17 L/min. Variability between measurements with the two techniques was decreased to 3.41+/-46.78 mL kg(-1) min(-1) when CO was normalized for body size by calculation of cardiac index.
Similar articles
-
Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method.Am J Crit Care. 2005 Jan;14(1):40-5. Am J Crit Care. 2005. PMID: 15608107
-
Comparison of noninvasive cardiac output measured by use of partial carbon dioxide rebreathing or the lithium dilution method in anesthetized foals.Am J Vet Res. 2007 Feb;68(2):141-7. doi: 10.2460/ajvr.68.2.141. Am J Vet Res. 2007. PMID: 17269878 Clinical Trial.
-
Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study.Int J Nurs Stud. 2009 Oct;46(10):1291-7. doi: 10.1016/j.ijnurstu.2009.03.013. Epub 2009 May 6. Int J Nurs Stud. 2009. PMID: 19423107
-
Noninvasive cardiac output determination: broadening the applicability of hemodynamic monitoring.Semin Cardiothorac Vasc Anesth. 2009 Mar;13(1):44-55. doi: 10.1177/1089253208330711. Epub 2009 Jan 14. Semin Cardiothorac Vasc Anesth. 2009. PMID: 19147529 Review.
-
[Arterial pressure-based cardiac output monitoring: 1. FloTrac sensor and SVV].Masui. 2009 Jul;58(7):838-47. Masui. 2009. PMID: 19618824 Review. Japanese.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous