Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 Mar;29(9):1177-88.
doi: 10.1016/j.biomaterials.2007.11.034.

Osteogenicity of biphasic calcium phosphate ceramics and bone autograft in a goat model

Affiliations
Free article
Comparative Study

Osteogenicity of biphasic calcium phosphate ceramics and bone autograft in a goat model

Borhane H Fellah et al. Biomaterials. 2008 Mar.
Free article

Abstract

The aim of this work was to compare the osteogenicity of calcium phosphate ceramic granules with autologous bone graft in ectopic and orthotopic sites. Biphasic calcium phosphate (BCP) granules composed of hydroxyapatite (HA) and beta-tricalcium phosphate (beta-TCP) in a 60/40 ratio were sintered at 1050, 1125 and 1200 degrees C, producing different microporosities. Either BCP ceramic granules or autologous bone chips (n=7) were implanted into paraspinal muscles. Osteoinduction was not observed in either the BCP implants or autologous bone chips after 6 or 12 weeks in the ectopic sites. Hollow and bored polytetrafluoroethylene (PTFE) cylinders were filled with autologous bone, BCP granules or left empty, then implanted into critical-sized defects in femoral epiphyses. The PTFE cylinders left empty contained marrow and blood vessels but not mineralized bone, indicating that this model prevented bone ingrowth (0.56+/-0.43% at 12 weeks). Bone formation was observed in contact with the BCP1050 and BCP1125 granules in the femoral sites after 6 weeks. The amount of bone after 12 weeks was 5.6+/-7.3 and 9.6+/-6.6% for BCP1050 and BCP1125, respectively. Very little bone formation was observed with the BCP1200 implants (1.5+/-1.3% at 12 weeks). In both the ectopic and orthotopic sites, autologous bone chips were drastically resorbed (from 19.4+/-3.7% initially to 1.7+/-1.2% at 12 weeks). This study shows that synthetic bone substitutes may have superior stability and osteogenic properties than autologous bone grafts in critical-sized bone defects.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources