Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 Feb;46(2):727-31.
doi: 10.1128/JCM.01540-07. Epub 2007 Dec 19.

Simultaneous detection of Chlamydophila pneumoniae and Mycoplasma pneumoniae by use of molecular beacons in a duplex real-time PCR

Affiliations
Comparative Study

Simultaneous detection of Chlamydophila pneumoniae and Mycoplasma pneumoniae by use of molecular beacons in a duplex real-time PCR

Karolina Gullsby et al. J Clin Microbiol. 2008 Feb.

Abstract

A real-time PCR was designed for detection of Chlamydophila pneumoniae and Mycoplasma pneumoniae such that each pathogen could be detected in a single tube and differentiated using molecular beacons marked with different fluorochromes. This duplex PCR, targeting the P1 adhesion gene for M. pneumoniae and the ompA gene for C. pneumoniae, was compared with two conventional PCR assays targeting the 16S rRNA gene and the ompA gene. A total of 120 clinical throat and nasopharyngeal swab samples were tested. DNA extraction was performed using an alkali denaturation/neutralization method, and real-time amplification, detection, and data analysis were performed using a Rotor-Gene 2000 real-time rotary analyzer (Corbett Life Science, Sydney, Australia). Using conventional PCR as a reference in an analysis of 120 samples, 13 of 14 samples positive for C. pneumoniae were detected by the novel real-time PCR. In an analysis of M. pneumoniae, 22 samples were positive in the conventional PCR and the novel assay detected 24 positive samples. When using the conventional PCR as a reference, sensitivity and specificity were 93% and 100%, respectively, for C. pneumoniae and 100% and 98%, respectively, for M. pneumoniae. With an overall agreement of 98.8%, this suggests that performance of the new duplex real-time PCR is comparable to that of conventional PCR.

PubMed Disclaimer

References

    1. Almirall, J., I. Morato, F. Riera, A. Verdaguer, R. Priu, P. Coll, J. Vidal, L. Murgui, F. Valls, F. Catalan, et al. 1993. Incidence of community-acquired pneumonia and Chlamydia pneumoniae infection: a prospective multicentre study. Eur. Respir. J. 614-18. - PubMed
    1. Apfalter, P., W. Barousch, M. Nehr, A. Makristathis, B. Willinger, M. Rotter, and A. M. Hirschl. 2003. Comparison of a new quantitative ompA-based real-time PCR TaqMan assay for detection of Chlamydia pneumoniae DNA in respiratory specimens with four conventional PCR assays. J. Clin. Microbiol. 41592-600. - PMC - PubMed
    1. Atmar, R. L., and S. B. Greenberg. 1989. Pneumonia caused by Mycoplasma pneumoniae and the TWAR agent. Semin. Respir. Infect. 419-31. - PubMed
    1. Bitnun, A., E. L. Ford-Jones, M. Petric, D. MacGregor, H. Heurter, S. Nelson, G. Johnson, and S. Richardson. 2001. Acute childhood encephalitis and Mycoplasma pneumoniae. Clin. Infect. Dis. 321674-1684. - PubMed
    1. Boelen, E., H. W. Steinbusch, A. J. van der Ven, G. Grauls, C. A. Bruggeman, and F. R. Stassen. 2007. Chlamydia pneumoniae infection of brain cells: an in vitro study. Neurobiol. Aging 28524-532. - PubMed

Publication types

MeSH terms

LinkOut - more resources