. 2007 Sep-Oct;73(5):633-9.
doi: 10.1016/s1808-8694(15)30123-3.

Tympanometry in neonates with normal otoacoustic emissions: measurements and interpretation

Affiliations

Tympanometry in neonates with normal otoacoustic emissions: measurements and interpretation

Kilza de Arruda Lyra e Silva et al. Braz J Otorhinolaryngol. 2007 Sep-Oct.

Abstract

Tympanometry is used in evaluating middle ear functional conditions. Before six months of age its results may be misleading. High frequency studies aim to provide more valid procedures.

Aim: To describe and discuss tympanometric measurements and the interpretation in normal hearing neonates at 226, 678 and 1000Hz.

Method: 110 neonates that were analyzed had normal otoacoustic emissions and no risk for hearing impairment. The age range was 6 to 30 days. Curves were obtained using the GSI-33-II, at the Divisão de Educação e Reabilitação dos Distúrbios da Comunicação, São Paulo, in 2004.

Study design: Clinical prospective.

Results: There was a balance between single and double peak curves at 226Hz. Most of the curves were asymmetric at 678Hz, and single-peaked at 1000Hz. quantitative measurements showed a significant gender difference in the Equivalent Ear Canal Volume at 226Hz and on the Peak Compensated Static Acoustic Admittance at 1000Hz. The English protocol showed that almost 100% of ears were normal at 678 and 1000Hz.

Conclusion: 1000Hz yielded superior results for characterizing normality. The English protocol was efficient to reduce the variability of tympanometric measurements. Data from this study may be used as a guide for diagnosis using tympanometry in neonates.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Yoshinaga-Itano C, Sedey AL, Coulter DK, Mehl AL. Language of early- and later-identified children with hearing loss. Pediatrics. 1998;102:1161–1171. - PubMed
    1. Sininger YS. Audiologic assessment in infants. Current Opinion in Otolaryngology & Head and Neck Surgery. 2003;11:378–382. - PubMed
    1. Margolis RH, Bass-Ringdahl S, Hanks WD, Holte L, Zapala DA. Tympanometry in newborn infants: 1kHz norms. J Am Acad Audiol. 2003;14:383–392. - PubMed
    1. Llly DJ. In: Handbook of clinical audiology. Katz J., editor. Willians & Wilkins; Baltimore: 1972. Acoustic impedance at the tympanic membrane; pp. 434–469.
    1. Paradise JL, Smith CG, Bluestone CD. Tympanometric detection of middle ear effusion in infants and young children. Pediatrics. 1976;58:198–210. - PubMed

Uncited Reference

    1. Joint Committee on Infant Hearing Year 2000 position statement: principles and guidelines for early hearing detection and intervention programs. Pediatrics. 2000;106:798–817. - PubMed
    1. Jerger J. Clinical experience with impedance audiometry. Arch Otolaryngol. 1970;92:311–324. - PubMed