Systematic variation of off-resonance prepulses for clinical magnetization transfer contrast imaging at 0.2, 1.5, and 3.0 tesla
- PMID: 18097273
- DOI: 10.1097/RLI.0b013e3181559949
Systematic variation of off-resonance prepulses for clinical magnetization transfer contrast imaging at 0.2, 1.5, and 3.0 tesla
Abstract
Objectives: The aim of the presented study was to evaluate pulsed magnetization transfer contrast (MTC) effects using saturation pulses of variable off-resonance frequency and radio frequency (RF) amplitude for a variety of tissue types (white and gray matter, liver, kidney, spleen, muscle, and articular cartilage) in human subjects at field strengths of 0.2, 1.5, and 3.0 Tesla.
Materials and methods: MTC imaging studies of the head, knee, and abdomen were performed using an adapted multiple MTC (mMTC) module in 3 healthy volunteers for all field strengths. This mMTC pulse module applies a variable Gaussian shaped magnetization transfer (MT) saturation pulse in a proton-density weighted RF-spoiled gradient echo sequence. It allows for both a flexible MT pulse design and performance of consecutive measurements with variation of amplitude and off-resonance frequency, whereas keeping other MT pulse parameters unchanged. Magnetization transfer signal ratio (MTR) maps were calculated on a pixel-by-pixel basis. Additional mMTC imaging measurements were performed using an agar-water phantom. For assessment of undesired direct saturation effects of the MT pulse on the water pool, numerical simulations based on Bloch's equations were performed and analyzed.
Results: The results indicate that MTR values for given MT pulses (pulse shape, off-resonance frequency and flip angle) are larger at higher magnetic field strengths. For white matter, gray matter, cartilage, and muscle, an increase of 10% to 30% was found at 3.0 T when compared with 1.5 T. Low magnetic field strength of 0.2 T led to MTR values of one third to half the values at 1.5 T. MTR values for abdominal tissues were partly lower at 3.0 T compared with 1.5 T, which might be related to reduced B1 field strengths at 3.0 T due to dielectric effects.
Conclusions: The increased MT effect at a higher field strength can partly compensate the specific absorption rate related problems in MTC applications. It is shown that for flip angles of 700 degrees to 900 degrees and offset frequencies of 1000 Hz to 1500 Hz, high quality MTR maps could be obtained at an acceptable level of direct saturation for all field strengths. Furthermore, if the better signal-to-noise ratio at higher magnetic fields is taken into account, quality of MTR maps of the head and the knee at 3.0 T was clearly improved compared with lower fields under optimized and comparable conditions.
Similar articles
-
A fast B1-mapping method for the correction and normalization of magnetization transfer ratio maps at 3 T.Neuroimage. 2010 Feb 15;49(4):3015-26. doi: 10.1016/j.neuroimage.2009.11.054. Epub 2009 Dec 4. Neuroimage. 2010. PMID: 19948229
-
Whole-body magnetization transfer contrast imaging.J Magn Reson Imaging. 2006 Nov;24(5):1183-7. doi: 10.1002/jmri.20754. J Magn Reson Imaging. 2006. PMID: 17031816
-
Quantitative magnetization transfer by trains of radio frequency pulses in human brain: extension of a free evolution model to continuous-wave-like conditions.Magn Reson Imaging. 2005 Jul;23(6):723-31. doi: 10.1016/j.mri.2005.05.005. Magn Reson Imaging. 2005. PMID: 16198827 Clinical Trial.
-
Imaging of the musculoskeletal system in vivo using ultra-high field magnetic resonance at 7 T.Invest Radiol. 2009 Sep;44(9):613-8. doi: 10.1097/RLI.0b013e3181b4c055. Invest Radiol. 2009. PMID: 19652609 Review.
-
Magnetization transfer magnetic resonance imaging: a clinical review.Top Magn Reson Imaging. 1996 Aug;8(4):214-30. Top Magn Reson Imaging. 1996. PMID: 8870180 Review.
Cited by
-
Magnetization transfer imaging reveals geniculocalcarine and striate area degeneration in primary glaucoma: a preliminary study.Acta Radiol Open. 2016 Sep 8;5(9):2058460116666876. doi: 10.1177/2058460116666876. eCollection 2016 Sep. Acta Radiol Open. 2016. PMID: 27651931 Free PMC article.
-
Magnetisation transfer MR imaging of the kidney: evaluation at 3.0 T in association with renal function.Eur Radiol. 2013 Aug;23(8):2315-9. doi: 10.1007/s00330-013-2841-y. Epub 2013 Apr 17. Eur Radiol. 2013. PMID: 23591620
-
The application of T1 and T2 relaxation time and magnetization transfer ratios to the early diagnosis of patellar cartilage osteoarthritis.Skeletal Radiol. 2009 Nov;38(11):1055-62. doi: 10.1007/s00256-009-0769-8. Epub 2009 Aug 18. Skeletal Radiol. 2009. PMID: 19688346
-
Incidental magnetization transfer contrast by fat saturation preparation pulses in multislice Look-Locker echo planar imaging.Magn Reson Med. 2009 Aug;62(2):520-6. doi: 10.1002/mrm.22034. Magn Reson Med. 2009. PMID: 19526506 Free PMC article.
-
Ultrashort echo time magnetization transfer (UTE-MT) imaging of cortical bone.NMR Biomed. 2015 Jul;28(7):873-80. doi: 10.1002/nbm.3316. Epub 2015 May 18. NMR Biomed. 2015. PMID: 25981914 Free PMC article.