Equipment-related electrocardiographic artifacts: causes, characteristics, consequences, and correction
- PMID: 18156892
- DOI: 10.1097/01.anes.0000296537.62905.25
Equipment-related electrocardiographic artifacts: causes, characteristics, consequences, and correction
Abstract
Interference of the monitored or recorded electrocardiogram is common within operating room and intensive care unit environments. Artifactual signals, which corrupt the normal cardiac signal, may arise from internal or external sources. Electrical devices used in the clinical setting can induce artifacts by various different mechanisms. Newer diagnostic and therapeutic modalities may generate artifactual changes. These artifacts may be nonspecific or may resemble serious arrhythmia. Clinical signs, along with monitored waveforms from other simultaneously monitored parameters, may provide the clues to differentiate artifacts from true changes on the electrocardiogram. Simple measures, such as proper attention to basic principles of electrocardiographic measurement, can eliminate some artifacts. However, in persistent cases, expert help may be required to identify the precise source and minimize interference on the electrocardiogram. Technological advancements in processing the electrocardiographic signal may be useful to detect and eliminate artifacts. Ultimately, an improved understanding of the artifacts generated by equipment, and their identifying characteristics, is important to avoid misinterpretation, misdiagnosis, and iatrogenic complication.
Comment in
-
Electrocardiographic ST-segment depression: confirm, deny, or artifact?Anesthesiology. 2008 Aug;109(2):352; author reply 352. doi: 10.1097/ALN.0b013e31817f4ccc. Anesthesiology. 2008. PMID: 18648245 No abstract available.
Similar articles
-
Artifactual ECG changes induced by electrocautery in a patient with coronary artery disease.J Electrocardiol. 2017 Jul-Aug;50(4):531-533. doi: 10.1016/j.jelectrocard.2017.03.005. Epub 2017 Mar 14. J Electrocardiol. 2017. PMID: 28347479
-
A micropower dry-electrode ECG preamplifier.IEEE Trans Biomed Eng. 2000 Feb;47(2):155-62. doi: 10.1109/10.821734. IEEE Trans Biomed Eng. 2000. PMID: 10721622
-
A simple solution for electrocardiographic artifacts during cardiopulmonary bypass and in the intensive care unit.J Cardiothorac Vasc Anesth. 2007 Aug;21(4):572-3. doi: 10.1053/j.jvca.2006.12.003. Epub 2007 Feb 22. J Cardiothorac Vasc Anesth. 2007. PMID: 17678789 No abstract available.
-
What is inside the electrocardiograph?J Electrocardiol. 2008 Jan-Feb;41(1):8-14. doi: 10.1016/j.jelectrocard.2007.08.059. J Electrocardiol. 2008. PMID: 18191652 Review.
-
The problem of artifacts in patient monitor data during surgery: a clinical and methodological review.Anesth Analg. 2006 Nov;103(5):1196-204. doi: 10.1213/01.ane.0000247964.47706.5d. Anesth Analg. 2006. PMID: 17056954 Review.
Cited by
-
Macrophage activation in stellate ganglia contributes to lung injury-induced arrhythmogenesis in male rats.Acta Physiol (Oxf). 2021 Jun;232(2):e13657. doi: 10.1111/apha.13657. Epub 2021 Apr 14. Acta Physiol (Oxf). 2021. PMID: 33817984 Free PMC article.
-
Monitor screen display inversion: Potential for risk during anaesthesia.Indian J Anaesth. 2014 May;58(3):368-9. doi: 10.4103/0019-5049.135101. Indian J Anaesth. 2014. PMID: 25024502 Free PMC article. No abstract available.
-
Amplitude spectrum area is dependent on the electrocardiogram magnitude: evaluation of different normalization approaches.Physiol Meas. 2024 Nov 25;45(11):10.1088/1361-6579/ad9233. doi: 10.1088/1361-6579/ad9233. Physiol Meas. 2024. PMID: 39536707
-
Reference Ranges of Glycemic Variability in Infants after Surgery-A Prospective Cohort Study.Nutrients. 2022 Feb 10;14(4):740. doi: 10.3390/nu14040740. Nutrients. 2022. PMID: 35215390 Free PMC article.
-
Apparent Pacer Spikes in a Patient with Back and Chest Pain.Clin Pract Cases Emerg Med. 2019 Feb 26;3(2):164-165. doi: 10.5811/cpcem.2019.1.41095. eCollection 2019 May. Clin Pract Cases Emerg Med. 2019. PMID: 31061979 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources