Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Dec;70(6):1136-40.
doi: 10.1016/j.urology.2007.07.067.

Targeted biopsy of the prostate: the impact of color Doppler imaging and elastography on prostate cancer detection and Gleason score

Affiliations

Targeted biopsy of the prostate: the impact of color Doppler imaging and elastography on prostate cancer detection and Gleason score

Eric D Nelson et al. Urology. 2007 Dec.

Abstract

Objectives: To compare detection of prostate cancer and distribution of Gleason scores with gray-scale, color Doppler, and elastographic imaging.

Methods: Prostate biopsy patients were evaluated with gray-scale, color Doppler, and elastographic imaging. Targeted biopsy cores were obtained along with six laterally directed systematic sextant cores. Pathologic results were correlated with imaging findings.

Results: Prostate cancer was detected in 60 of 137 patients (43.8%). Cancer was detected in 241 (14%) of 1703 biopsy cores, including 90 (20%) of 448 targeted cores, 106 (13%) of 818 sextant cores, and 45 (10%) of 437 transition zone cores. Sonographic abnormality was associated with cancer: gray-scale odds ratio (OR) = 3.19, P = 0.011; color Doppler OR = 1.86, P = 0.041; elastography OR = 2.53; P = 0.007. Although targeted cores were more likely than sextant cores to detect cancer (OR = 1.82, P = 0.004), no sonographic abnormality was found in 57 (53.8%) of 106 of positive sextant sites. A linear trend for increasing Gleason score was present with gray-scale (P <0.001) imaging, color Doppler imaging (P <0.005), and elastography (P <0.001). Abnormal color flow was strongly associated with Gleason score 8 to 10 lesions but not with lower-grade lesions. Elastography demonstrated a positive association with Gleason scores of 5 to 10.

Conclusions: Targeted cores based on gray-scale, color Doppler, and elastographic imaging are more likely to return positive biopsy results as compared with systematic biopsy cores. Although color Doppler imaging and elastography are encouraging adjuncts to improve cancer detection, targeted biopsy alone is not sufficient to replace the traditional sextant biopsy technique.

PubMed Disclaimer