Evaluation of a multimode fiber optic low coherence interferometer for path length resolved Doppler measurements of diffuse light
- PMID: 18163752
- DOI: 10.1063/1.2823558
Evaluation of a multimode fiber optic low coherence interferometer for path length resolved Doppler measurements of diffuse light
Abstract
The performance of a graded index multimode fiber optic low coherence Mach-Zehnder interferometer with phase modulation is analyzed. Investigated aspects were its ability to measure path length distributions and to perform path length resolved Doppler measurements of multiple scattered photons in a turbid suspension of particles undergoing Brownian and translational motion. The path length resolution of this instrument is compared with a system using single mode fibers for illumination and detection. The optical path lengths are determined from the zero order moment of the phase modulation peak in the power spectrum. The weighted first moment, which is equal to the average Doppler shift, shows a linear response for different mean flow velocities within the physiological range.
Similar articles
-
Path-length-resolved measurements of multiple scattered photons in static and dynamic turbid media using phase-modulated low-coherence interferometry.J Biomed Opt. 2007 Mar-Apr;12(2):024020. doi: 10.1117/1.2714795. J Biomed Opt. 2007. PMID: 17477735
-
In vivo optical path lengths and path length resolved doppler shifts of multiply scattered light.Lasers Surg Med. 2010 Nov;42(9):692-700. doi: 10.1002/lsm.20969. Lasers Surg Med. 2010. PMID: 20976809 Clinical Trial.
-
Common-path optical coherence tomography with side-viewing bare fiber probe for endoscopic optical coherence tomography.Rev Sci Instrum. 2007 Nov;78(11):113102. doi: 10.1063/1.2804112. Rev Sci Instrum. 2007. PMID: 18052460
-
Implantable hearing device performance measured by laser Doppler interferometry.Ear Nose Throat J. 1997 May;76(5):297-9, 302, 305-9. Ear Nose Throat J. 1997. PMID: 9170711 Review.
-
Some aspects of the use of laser Doppler flow meters for recording tissue blood flow.Exp Physiol. 1993 Jan;78(1):1-14. doi: 10.1113/expphysiol.1993.sp003664. Exp Physiol. 1993. PMID: 8448007 Review.
Cited by
-
Low-Coherence Interferometric Fiber Optic Sensor for Humidity Monitoring Based on Nafion® Thin Film.Sensors (Basel). 2019 Feb 2;19(3):629. doi: 10.3390/s19030629. Sensors (Basel). 2019. PMID: 30717331 Free PMC article.
-
Study on Laser Parameter Measurement System Based on Cone-Arranged Fibers and CCD Camera.Sensors (Basel). 2022 Oct 17;22(20):7892. doi: 10.3390/s22207892. Sensors (Basel). 2022. PMID: 36298246 Free PMC article.
-
Combined multimodal optical imaging and targeted gene silencing using stimuli-transforming nanotheragnostics.J Am Chem Soc. 2010 Jun 23;132(24):8316-24. doi: 10.1021/ja100580y. J Am Chem Soc. 2010. PMID: 20518502 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources