Introduction to rodent cardiac imaging
- PMID: 18172331
- DOI: 10.1093/ilar.49.1.27
Introduction to rodent cardiac imaging
Abstract
Imaging is a noninvasive complement to traditional methods (such as histology) in rodent cardiac studies. Assessments of structure and function are possible with ultrasound, microcomputed tomography (microCT), and magnetic resonance (MR) imaging. Cardiac imaging in the rodent poses a challenge because of the size of the animal and its rapid heart rate. Each aspect in the process of rodent cardiac imaging-animal preparation, choice of anesthetic, selection of gating method, image acquisition, and image interpretation and measurement-requires careful consideration to optimize image quality and to ensure accurate and reproducible data collection. Factors in animal preparation that can affect cardiac imaging are the choice of anesthesia regime (injected or inhaled), intubated or free-breathing animals, physiological monitoring (ECG, respiration, and temperature), and animal restraint. Each will vary depending on the method of imaging and the length of the study. Gating strategies, prospective or retrospective, reduce physiological motion artifacts and isolate specific time points in the cardiac cycle (i.e., end-diastole and end-systole) where measurements are taken. This article includes a simple explanation of the physics of ultrasound, microCT, and MR to describe how images are generated. Subsequent sections provide reviews of animal preparation, image acquisition, and measurement techniques in each modality specific to assessing cardiac functions such as ejection fraction, fractional shortening, stroke volume, cardiac output, and left ventricular mass. The discussion also includes the advantages and disadvantages of the different imaging modalities. With the use of ultrasound, microCT, and MR, it is possible to create 2-, 3-, and 4-dimensional views to characterize the structure and function of the rodent heart.
Similar articles
-
Intrinsic gating for small-animal computed tomography: a robust ECG-less paradigm for deriving cardiac phase information and functional imaging.Circ Cardiovasc Imaging. 2008 Nov;1(3):235-43. doi: 10.1161/CIRCIMAGING.108.784702. Circ Cardiovasc Imaging. 2008. PMID: 19808548
-
Cardiac volumetry. Comparison of echoplanar and conventional cine-magnetic resonance data-acquisition strategies.Invest Radiol. 1994 Nov;29(11):994-1000. Invest Radiol. 1994. PMID: 7890515
-
Prospective respiratory-gated micro-CT of free breathing rodents.Med Phys. 2005 Sep;32(9):2888-98. doi: 10.1118/1.2013007. Med Phys. 2005. PMID: 16266103
-
European Association of Cardiovascular Imaging/Cardiovascular Imaging Department of the Brazilian Society of Cardiology recommendations for the use of cardiac imaging to assess and follow patients after heart transplantation.Eur Heart J Cardiovasc Imaging. 2015 Sep;16(9):919-48. doi: 10.1093/ehjci/jev139. Epub 2015 Jul 2. Eur Heart J Cardiovasc Imaging. 2015. PMID: 26139361 Review.
-
Motion in cardiovascular MR imaging.Radiology. 2009 Feb;250(2):331-51. doi: 10.1148/radiol.2502071998. Radiology. 2009. PMID: 19188310 Review.
Cited by
-
A deformable generic 3D model of haptoral anchor of Monogenean.PLoS One. 2013 Oct 28;8(10):e77650. doi: 10.1371/journal.pone.0077650. eCollection 2013. PLoS One. 2013. PMID: 24204903 Free PMC article.
-
Integrated optical coherence tomography and multielement ultrasound transducer probe for shear wave elasticity imaging of moving tissues.J Biomed Opt. 2018 Oct;23(10):1-7. doi: 10.1117/1.JBO.23.10.105006. J Biomed Opt. 2018. PMID: 30369107 Free PMC article.
-
In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography.J Vis Exp. 2016 Feb 16;(108):53603. doi: 10.3791/53603. J Vis Exp. 2016. PMID: 26967592 Free PMC article.
-
Characterization of a murine xenograft model for contrast agent development in breast lesion malignancy assessment.J Biomed Sci. 2016 May 17;23(1):46. doi: 10.1186/s12929-016-0261-4. J Biomed Sci. 2016. PMID: 27188327 Free PMC article.
-
Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray.Med Phys. 2010 Oct;37(10):5306-12. doi: 10.1118/1.3491806. Med Phys. 2010. PMID: 21089765 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources