The impact of NSF on the care of patients with kidney disease
- PMID: 18180009
- DOI: 10.1016/j.jacr.2007.08.018
The impact of NSF on the care of patients with kidney disease
Abstract
The association of nephrogenic systemic fibrosis (NSF) with the use of gadolinium-based magnetic resonance contrast agents (GBMCAs) has greatly affected the care of patients with kidney disease. Nephrogenic systemic fibrosis has been reported in patients with end-stage renal disease, chronic kidney disease (CKD) and acute kidney injury. The majority of cases have occurred in patients with end-stage renal disease, but cases of NSF have been reported in CKD patients with glomerular filtration rates less than 30 mL/min/1.73 m(2). Odds ratios have ranged between 8.97 and 32.5 among patients exposed to GBMCAs. Given the significant morbidity, disability, and mortality associated with NSF, it is imperative to properly and preemptively identify those patients at risk. Patients with end-stage renal disease seem to be at highest risk, particularly those maintained on peritoneal dialysis (PD). Although there are no data to support a role for hemodialysis in reducing the risk for NSF after the administration of GBMCAs, hemodialysis is recommended within 2 to 3 hours. Patients maintained on PD and those with CKD present a challenge, as they do not typically have vascular access for hemodialysis, yet the clearance of GBMCAs is very low, and it may be prudent to consider hemodialysis especially for PD patients. Gadolinium-based magnetic resonance contrast agents are removed by dialysis, with estimates that about 99% of a dose is removed after 3 to 4 sessions of hemodialysis. The elimination half-life averaged 9 hours in patients with stage 4 CKD (glomerular filtration rate <30 mL/min/1.73 m(2)) compared with 1.5 hours in those with normal glomerular filtration rates. This prolonged elimination and longer exposure may be important factors in predisposing to NSF.
Similar articles
-
Nephrogenic systemic fibrosis and gadolinium-based contrast agents.Adv Chronic Kidney Dis. 2011 May;18(3):188-98. doi: 10.1053/j.ackd.2011.03.001. Adv Chronic Kidney Dis. 2011. PMID: 21531325 Review.
-
[Nephrogenic systemic fibrosis].Med Monatsschr Pharm. 2009 Oct;32(10):377-82. Med Monatsschr Pharm. 2009. PMID: 19886227 Review. German.
-
Nephrogenic systemic fibrosis--implications for nephrologists.Eur J Radiol. 2008 May;66(2):208-12. doi: 10.1016/j.ejrad.2008.01.028. Epub 2008 Mar 14. Eur J Radiol. 2008. PMID: 18342470 Review.
-
Gadolinium-containing magnetic resonance imaging contrast and nephrogenic systemic fibrosis: a case-control study.Am J Kidney Dis. 2008 Jun;51(6):966-75. doi: 10.1053/j.ajkd.2007.12.036. Epub 2008 Mar 25. Am J Kidney Dis. 2008. PMID: 18501784
-
Gadolinium-induced nephrogenic systemic fibrosis in a patient with an acute and transient kidney injury.Br J Dermatol. 2008 Mar;158(3):607-10. doi: 10.1111/j.1365-2133.2007.08369.x. Epub 2007 Dec 11. Br J Dermatol. 2008. PMID: 18076707
Cited by
-
Gadolinium-Based Contrast Agents in Kidney Disease: A Comprehensive Review and Clinical Practice Guideline Issued by the Canadian Association of Radiologists.Can J Kidney Health Dis. 2018 Jun 12;5:2054358118778573. doi: 10.1177/2054358118778573. eCollection 2018. Can J Kidney Health Dis. 2018. PMID: 29977584 Free PMC article.
-
Ligand-directed nanobialys as theranostic agent for drug delivery and manganese-based magnetic resonance imaging of vascular targets.J Am Chem Soc. 2008 Jul 23;130(29):9186-7. doi: 10.1021/ja801482d. Epub 2008 Jun 24. J Am Chem Soc. 2008. PMID: 18572935 Free PMC article.
-
Synthesis of NanoQ, a copper-based contrast agent for high-resolution magnetic resonance imaging characterization of human thrombus.J Am Chem Soc. 2011 Jun 22;133(24):9168-71. doi: 10.1021/ja201918u. Epub 2011 May 26. J Am Chem Soc. 2011. PMID: 21599030 Free PMC article.
-
Sensitive and efficient detection of thrombus with fibrin-specific manganese nanocolloids.Chem Commun (Camb). 2009 Jun 14;(22):3234-6. doi: 10.1039/b902875g. Epub 2009 Apr 22. Chem Commun (Camb). 2009. PMID: 19587924 Free PMC article.
-
Magnetic resonance imaging contrast enhancement in vitro and in vivo by octanuclear iron-oxo cluster-based agents.J Inorg Biochem. 2018 Sep;186:176-186. doi: 10.1016/j.jinorgbio.2018.06.005. Epub 2018 Jun 26. J Inorg Biochem. 2018. PMID: 29957454 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical