The adsorption of vancomycin by polyacrylonitrile, polyamide, and polysulfone hemofilters
- PMID: 18181809
- DOI: 10.1111/j.1525-1594.2007.00460.x
The adsorption of vancomycin by polyacrylonitrile, polyamide, and polysulfone hemofilters
Abstract
The aim of this study was to characterize vancomycin adsorption by polyacrylonitrile (PAN), polyamide, and polysulfone hemofilters using an in vitro model of hemofiltration. Vancomycin (36 mg) was added to a blood-crystalloid mixture of known volume (target concentration of 50 mg/L) and pumped around a closed circuit. Adsorption, which was calculated from the fall in concentration over 120 min, was significantly greater by 0.6-m(2) PAN filters (10.08 +/- 2.26 mg) than by 0.6-m(2) polyamide (5.20 +/- 1.82 mg) or 0.7-m(2) polysulfone (4.80 +/- 2.40 mg) filters (P < 0.05). Cumulative adsorption was not changed by the addition of 500-mL lactated Ringer's solution (to reduce the circulating vancomycin concentration). These data show that although adsorption of vancomycin by PAN, polyamide, and polysulfone hemofilters occurs, the absolute adsorption is small. Adsorption is dependent on filter material and is not reversed by a decrease in circulating concentration.
Similar articles
-
Effect of drug concentration on adsorption of levofloxacin by polyacrylonitrile haemofilters.Int J Antimicrob Agents. 2006 Aug;28(2):147-50. doi: 10.1016/j.ijantimicag.2006.03.025. Epub 2006 Jul 18. Int J Antimicrob Agents. 2006. PMID: 16854570
-
Adsorption of amikacin, a significant mechanism of elimination by hemofiltration.Antimicrob Agents Chemother. 2008 Mar;52(3):1009-13. doi: 10.1128/AAC.00858-07. Epub 2007 Dec 17. Antimicrob Agents Chemother. 2008. PMID: 18086842 Free PMC article.
-
Permeability decay in CAVH hemofilters.ASAIO Trans. 1988 Jul-Sep;34(3):590-3. ASAIO Trans. 1988. PMID: 3196568
-
Biocompatibility of the polyamide membranes.Contrib Nephrol. 1992;96:26-46. doi: 10.1159/000421121. Contrib Nephrol. 1992. PMID: 1740049 Review. No abstract available.
-
Present status and perspective of the development of a bioartificial kidney for chronic renal failure patients.Ther Apher Dial. 2006 Aug;10(4):342-7. doi: 10.1111/j.1744-9987.2006.00387.x. Ther Apher Dial. 2006. PMID: 16911187 Review.
Cited by
-
The use of SDS-PAGE scanning of spent dialysate to assess uraemic toxin removal by dialysis.Nephrol Dial Transplant. 2011 Jul;26(7):2281-9. doi: 10.1093/ndt/gfq709. Epub 2010 Dec 10. Nephrol Dial Transplant. 2011. PMID: 21148683 Free PMC article. Clinical Trial.
-
Different distances between central venous catheter tips can affect antibiotic clearance during continuous renal replacement therapy.Intensive Care Med Exp. 2024 Jun 24;12(1):56. doi: 10.1186/s40635-024-00635-6. Intensive Care Med Exp. 2024. PMID: 38913212 Free PMC article.
-
Reply to Baud and Houzé, "Should In Vitro and In Vivo Studies on Antimicrobial Agents during Continuous Renal Replacement Therapy Comply with General Principles of Pharmacokinetics?".Antimicrob Agents Chemother. 2020 May 21;64(6):e00401-20. doi: 10.1128/AAC.00401-20. Print 2020 May 21. Antimicrob Agents Chemother. 2020. PMID: 32439687 Free PMC article. No abstract available.
-
Effect of preexposure to aminoglycosides on in vitro adsorption of amikacin by polyacrylonitrile hemofilters.Antimicrob Agents Chemother. 2011 Jul;55(7):3641-2. doi: 10.1128/AAC.00541-10. Epub 2011 Apr 18. Antimicrob Agents Chemother. 2011. PMID: 21502614 Free PMC article. No abstract available.
-
Vancomycin Sequestration in ST Filters: An In Vitro Study.Antibiotics (Basel). 2023 Mar 21;12(3):620. doi: 10.3390/antibiotics12030620. Antibiotics (Basel). 2023. PMID: 36978488 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical