Laser lead extraction and baffle stenting to facilitate dual chamber implantable defibrillator upgrade in a patient with L-transposition of the great arteries status-post Senning/Rastelli repair: a case report and review of literature
- PMID: 18181924
- DOI: 10.1111/j.1540-8159.2007.00939.x
Laser lead extraction and baffle stenting to facilitate dual chamber implantable defibrillator upgrade in a patient with L-transposition of the great arteries status-post Senning/Rastelli repair: a case report and review of literature
Abstract
A case of successful laser extraction of a defibrillator lead with baffle stenting in a 15-year-old boy with dextrocardia, L-transposition, ventricular septal defect, and pulmonic stenosis status-post Senning/Rastelli repair is presented. Six-month follow-up revealed a significant increase in exercise tolerance and maximum oxygen consumption (VO(2)max).