In patients with DCIS: is it sufficient to histologically examine only those tissue specimens that contain microcalcifications?
- PMID: 18183402
- DOI: 10.1007/s00330-007-0846-0
In patients with DCIS: is it sufficient to histologically examine only those tissue specimens that contain microcalcifications?
Abstract
The purpose was to investigate in patients with histologically proven DCIS to what extent there is agreement between radiographically proven microcalcifications of specimens obtained by vacuum-assisted biopsy and the histologic diagnosis of microcalcifications and DCIS, and second, to assess the accuracy of biopsy in relation to the number of specimens obtained in patients with high-grade and low-grade DCIS. Four hundred twenty specimens from 35 patients who were diagnosed with DCIS were examined radiographically and histologically for the presence of microcalcifications. The results were analyzed using the McNemar-test. In addition, the average numbers of biopsy specimens necessary for diagnosing low-grade DCIS and high-grade DCIS were compared using the t-test. Specimen radiography had a PPV of 0.50 and a NPV of 0.85 for the demonstration of DCIS. Differences in localization between radiographically proven microcalcifications and DCIS were statistically significant (p<0.01). The difference between the mean numbers of specimens required per patient for correctly diagnosing high-grade or low-grade DCIS was statistically significant (p<0.01). Specimen radiography is very limited in identifying those specimens that are crucial for diagnosing DCIS. The rate of underestimation is expected to be higher for low-grade than for high-grade DCIS. The findings suggest that all samples obtained by vacuum-assisted breast biopsy should be histologically examined.
Comment in
-
Cores with microcalcifications in DCIS diagnosis: how many cores make the difference?Eur Radiol. 2008 Nov;18(11):2398. doi: 10.1007/s00330-008-1031-9. Epub 2008 May 24. Eur Radiol. 2008. PMID: 18500526 No abstract available.
Similar articles
-
Cores with microcalcifications in DCIS diagnosis: how many cores make the difference?Eur Radiol. 2008 Nov;18(11):2398. doi: 10.1007/s00330-008-1031-9. Epub 2008 May 24. Eur Radiol. 2008. PMID: 18500526 No abstract available.
-
Comparison of the diagnostic accuracy of a vacuum-assisted percutaneous intact specimen sampling device to a vacuum-assisted core needle sampling device for breast biopsy: initial experience.Breast J. 2006 Jul-Aug;12(4):302-8. doi: 10.1111/j.1075-122X.2006.00268.x. Breast J. 2006. PMID: 16848839
-
Indications for stereotactically-guided vacuum-assisted breast biopsy for patients with category 3 microcalcifications.Breast Cancer. 2007;14(3):285-91. doi: 10.2325/jbcs.14.285. Breast Cancer. 2007. PMID: 17690506
-
Mammographic features and correlation with biopsy findings using 11-gauge stereotactic vacuum-assisted breast biopsy (SVABB).Ann Oncol. 2004 Mar;15(3):450-4. doi: 10.1093/annonc/mdh088. Ann Oncol. 2004. PMID: 14998847 Review.
-