Patient-specific characteristics determine success of surgical atrial fibrillation ablation in patients with persistent atrial fibrillation
- PMID: 18187380
- DOI: 10.1532/HSF98.20071161
Patient-specific characteristics determine success of surgical atrial fibrillation ablation in patients with persistent atrial fibrillation
Abstract
Surgical atrial fibrillation ablation (SAFA) has not achieved the efficacy of Cox's original maze procedure, although technical improvements continue to be made. It is possible that biologic factors determine SAFA success. Therefore we examined how patient-specific characteristics affected SAFA success in 353 atrial fibrillation (AF) patients who underwent SAFA at a single institution. Among these, 257 (72.8%) had continuous AF and 96 (27.2%) had intermittent AF. For 297 patients (84.1%) postoperative follow-up was > 3 months. We compared SAFA success in patients whose procedure involved only pulmonary vein isolation with those whose procedure involved extensive lesion sets. Multivariate analysis included AF duration, left atrial size, preoperative atrial flutter, concomitant procedures, lesion sets, and energy source. Early SAFA success was classified as freedom from AF between postoperative months 3 and 6, and intermediate success between postoperative months 6 and 12. Receiver-operating characteristic (ROC) curves and stratum-specific likelihood ratios (SSLR) were generated to compare intermediate failure by left atrial size (LAS) thresholds. SAFA was more successful in the intermittent than the continuous AF group (n = 66, 86% vs n = 165, 71%; P = .014). When pulmonary vein isolation was compared only to more extensive lesion sets, there was no difference in success in the intermittent (34, 91% vs 32, 81%; P = .24) or continuous groups (67, 73% vs. 98, 69%; P = .603). Success for intermittent AF patients was not correlated with variables considered; in continuous AF patients, predictors included presence of concomitant mitral valve repair/replacement (P = .075), decreasing LAS (P = .025) and absence of preoperative atrial flutter (P = .001). In the continuous AF group, ROC curves and corresponding areas under the curve (AUC) were 0.60 (0.50-0.71) for failure at 6 months to 1 year. SSLR analysis generated 2 strata for LAS: < 8 cm with SSLR = 0.87 (0.74-1.0) and < or = 8 cm SSLR = 2.98 (1.07-8.3). In patients with intermittent AF, SAFA achieved acceptable results regardless of tested preoperative and intraoperative variables. In continuous AF, patient-specific characteristics affected success more than intraoperative variables. Failure was more than 3-fold greater in continuous AF patients with an LAS < or = 8 cm. In both patient types, more extensive lesion sets were not shown to improve outcomes. Future improvements in SAFA may depend on pharmacologic and/or surgical substrate modification.
Similar articles
-
Surgical ablation of atrial fibrillation: the Columbia Presbyterian experience.J Card Surg. 2006 Sep-Oct;21(5):441-8. doi: 10.1111/j.1540-8191.2006.00273.x. J Card Surg. 2006. PMID: 16948752
-
Right isthmus ablation reduces supraventricular arrhythmias after surgery for chronic atrial fibrillation.Ann Thorac Surg. 2008 Jan;85(1):39-48. doi: 10.1016/j.athoracsur.2007.07.056. Ann Thorac Surg. 2008. PMID: 18154775
-
Intraoperative radiofrequency ablation for the treatment of atrial fibrillation during concomitant cardiac surgery.Ann Thorac Surg. 2005 Jul;80(1):210-5; discussion 215-6. doi: 10.1016/j.athoracsur.2005.01.051. Ann Thorac Surg. 2005. PMID: 15975369
-
Surgical treatment of atrial fibrillation with concomitant mitral valve disease: an Asian review.Chang Gung Med J. 2008 Nov-Dec;31(6):538-45. Chang Gung Med J. 2008. PMID: 19241892 Review.
-
Catheter ablation of atrial fibrillation in the elderly: where do we stand?Cardiol J. 2009;16(2):113-20. Cardiol J. 2009. PMID: 19387957 Review.
Cited by
-
Modified Maze Procedure for Atrial Fibrillation as an Adjunct to Elective Cardiac Surgery: Predictors of Mid-Term Recurrence and Echocardiographic Follow-Up.Tex Heart Inst J. 2015 Aug 1;42(4):341-7. doi: 10.14503/THIJ-14-4554. eCollection 2015 Aug. Tex Heart Inst J. 2015. PMID: 26413016 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Medical